SPECIFICATIONS 

Model: 

Rated 

Voltage: 

    

Rated Power:   

Operating 

Time:    

Noise Levels (decibels):  

Coverage Area: 

 

 

Weight 

:      

Dimensions: 

     

Water 

Tank 

Capacity: 

   

Humidification Mode:

Timer:  

SimpleMist KR003

DC 24V

20 W

≥17H

≤38dB

Up to 400 sq. ft. (Up to 37m

2

)

3.5 lbs. (1.6 kg)

6.7” x 6.7” x 13.6” (17 x 17 x 34.5 cm)

1.3 gallons (5.0 L)

High: 300ml/h  Medium: 200ml/h  Low: 100ml/h

2/4/6/8/10/12 Hours

Summary of Contents for SimpleMist KR003

Page 1: ...Ultrasonic Humidifier CAUTION READ MANUAL CAREFULLY FOR PROPER PROCEDURES AND OPERATION 2h 4h 6h ...

Page 2: ...r our website www allergybuyersclub com TABLE OF CONTENTS Introduction 2 Specifications 3 Important Safety Instructions 4 Product Content Features 5 Operational Placement Parts Diagram 6 Getting Started 7 8 Control Panel Product Operation 9 Water Level Indicator 10 Anti Splash Function 10 Power Off Storage 11 Product Maintenance 12 Troubleshooting 13 Warranty 14 15 CORRECT DISPOSAL OF THIS PRODUCT...

Page 3: ...decibels Coverage Area Weight Dimensions Water Tank Capacity Humidification Mode Timer SimpleMist KR003 DC 24V 20 W 17H 38dB Up to 400 sq ft Up to 37m2 3 5 lbs 1 6 kg 6 7 x 6 7 x 13 6 17 x 17 x 34 5 cm 1 3 gallons 5 0 L High 300ml h Medium 200ml h Low 100ml h 2 4 6 8 10 12 Hours ...

Page 4: ...r use the humidifier if there is damage to the unit or the power cord To avoid electrical shock do not touch the humidifier power cord or plug when your hands are wet Only connect the humidifier to a 110 120V power source do not use with other equipment Only use the AC 24V 1A power cord that came with the unit Always unplug the humidifier before moving it or adding water Do not use the humidifier ...

Page 5: ... Outlet Control Panel Base CLEANABLE TIMER TOP REFILL ANTI SPLASH HIGH CAPACITY MIST OUTPUT AROMATHERAPY WATER LEVEL INDICATOR 2h 4h 6h ACCESSORIES Aromatherapy Cotton Pad 1 Cleaning Brush Adapter AC 100V 240V Water Level Float Ceramic Ball Water Softening Filter FEATURES ...

Page 6: ...read adhered to and followed before the unit is operated Incorrect operation may cause harm or damage Water Level Float Mist Chamber Cover Ceramic Ball Water Softening Filter Tank Mist Outlet Tank Outlet Mist Channel Mist Outlet Water Level Indicator Lights Ultrasonic Transducer Indicator Lights Power Button Power Jack Aromatherapy Box Bottom of Base Bottom of Tank ...

Page 7: ...el Float Bracket are in the correct direction according to the different size of the holes otherwise it may cause water leakage Step 2 Turn the humidifier base over and plug the Power Adapter into the bottom of the humidifier base Fit cord into notch at bottom of base Step 3 Insert the Ceramic Ball Water Softener Filter into the filter ring at the bottom of the Water Tank Bottom of Base Ceramic Ba...

Page 8: ...p 5 Cover the Water Tank plug in the power and the product is ready to use AROMATHERAPY If aromatherapy is desired remove the Aromatherapy Box by pressing on it Carefully add 2 to 3 droplets of 100 essential oil onto the supplied aromatherapy cotton pad Push box in when done until locked into place Do not use without SimpleMist aromatherapy cotton pads The aroma will be diffused into the mist when...

Page 9: ...e fan When the humidifier is first turned on the humidifier will be set to the 12 hour timer setting 1 Press the Timer Button once to set the humidifier to the 2 hour timer setting 2 Press the Timer Button a 2nd time to set the humidifier to the 4 hour timer setting 3 Press the Timer Button a 3rd time to set the humidifier to the 6 hour timer setting 4 Press the Timer Button a 4th time to set the ...

Page 10: ...er Level Indicator Lights ON Press and hold again for 1 5 seconds to turn the Water Level Indicator Lights OFF Any time the tank is removed while the humidifier is operating the mist function will automatically turn off The mist function will resume within 3 seconds after the tank is reinstalled properly 2h 4h 6h Water Level Indicator Light ...

Page 11: ...ly but it takes several minutes to power off the fan POWER OFF STORAGE PROCEDURE FOR STORAGE OR AN EXTENDED PERIOD OF NON USAGE 1 Remove the power plug and unplug from the electrical outlet 2 Remove the tank and pour out any remaining water 3 Allow tank to dry 4 Using a soft cloth wipe the base dry Power Adapter Water Tank Base ...

Page 12: ...ILTER Clean and re activate the water softening filter every 30 45 days 1 Remove the Water Softening Filter from the tank cover 2 Soak the Water Softening Filter in a 50 50 water and white vinegar mixture for approximately 10 minutes 3 Remove the Water Softening Filter from the water and white vinegar solution and thoroughly rinse with cool clean water 4 The Water Softening Filter is now ready for...

Page 13: ... inside the product affects the atomization efficiency 2 The transducer has aged 3 Dust gathering at the air filter blocking the air inlet 1 Remove the scale with a weak white vinegar water solution and then rinse with water 2 Contact Customer Service 3 Clean the air inlet Water Leakage 1 Tank is not correctly installed 2 The tank outlet s seal ring is improperly installed 3 Foreign body stuck ins...

Page 14: ...and within a reasonable period of time subject to the conditions herein if our examination shall disclose any part to be defective in workmanship or material If we in our discretion are unable to repair the product after a reasonable number of attempts we will provide either a refund of the purchase price or a replacement unit at the company s option WHAT IS NOT COVERED BY THIS WARRANTY Not for co...

Page 15: ...ch In such states the above limitations may not apply to you If any provision of this warranty or part thereof is held by a court of competent jurisdiction to be invalid illegal or unenforceable the validity legality and enforceability of the remaining provisions or parts thereof will not in any way be affected or impaired within the jurisdiction of that court This entire warranty shall continue t...

Page 16: ...e with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measur...