background image

4

3. 

Remove the protective film 
from the Velcro mounts.

4. 

Position the Air Scrubber Mini 
EM by Aerus unit over the 
Mini Split indoor intake.

5. 

Press firmly to attach to unit.

Your Air Scrubber Mini EM by Aerus requires no periodic maintenance beyond normal 
replacement of the ActivePure® Cell.  Instructions for replacement of the ActivePure Cell, as 
well as the ballast should it need to be replaced, are provided herein.  Please contact your 
independent HVAC contractor for service.  

Note: For optimal performance, we recommend the replacement of the ActivePure® Cell every year, 
even if the UV lamp appears to be operating normally. 

MAINTENANCE

S1

S2

S3

6. 

The power leads can be connected to the Mini Split HVAC power source typically 
through the back of the indoor unit. Some models may be different.

7. 

Remove any cover to the power connection 
points. Connect Black Lead to the S1 terminal. 
Connect White Lead to the S2 terminal.

8. 

Replace any cover over the power connection 
and dress wiring to prevent any possible 
damage to the leads. 

 
Once you have reconnected power to the Mini 
Split HVAC system, the Air Scrubber Mini EM 
by Aerus will automatically work using the 
Mini Split HVAC power source.

WARNING: 

  Before you begin installation, verify the Mini Split HVAC system 

is turned off and disconnected from the power source.  Failure 
to disconnect the power may result in severe electrical shock.

Summary of Contents for Air Scrubber Mini EM

Page 1: ...0703 VA 01223 READ AND KEEP THIS MANUAL FOR REFERENCE PURPOSES External Mount EM Air Treatment System Ozone Free Unit for Mini Split HVAC Systems Made in the USA 2017 SpaceTechnology Hall of Fame Indu...

Page 2: ...e name and phone number of your Independent HVAC Contractor Name ______________________________________________________________________ Phone __________________________________________________________...

Page 3: ...C system is turned off and disconnected from the power source Failure to disconnect the power may result in severe electrical shock CAUTION Never look directly at the ActivePure Cell while illuminated...

Page 4: ...ppears to be operating normally MAINTENANCE S1 S2 S3 6 The power leads can be connected to the Mini Split HVAC power source typically through the back of the indoor unit Some models may be different 7...

Page 5: ...sconnect the power may result in severe electrical shock 4 Slide a new ActivePure Cell bulb assembly the opposite direction into place 5 Reconnect the 4 wire connection and reinstall the two screws 6...

Page 6: ...ts 3 Remove 2 pin power plug from metal bracket Slide 4 wire connection out of bulb assembly connector 4 Slide new 4 wire connection into the bulb assembly connector and reconnect Replace 2 pin power...

Page 7: ...bevoided AirScrubberMiniEMbyAerusproductsareforsalethrough authorizedIndependentHVACContractorsonly Warrantiesarevoidedifa productispurchasedthroughunauthorizedchannels thisincludeswebsites thatarenot...

Page 8: ...in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to...