Ⅵ
. Protect function and Restart work method;
State description
Function
LED light
alarm
AC output
Restart work method
Input low
voltage alarm
Green on
Red off
Alarm
AC have output
When the voltage of the
batter return to the related
voltage, alarm stop
automatically.
Input low
voltage shut
down
Green on
Red on
No alarm
No AC output
When the voltage of the
batter return to the related
voltage the inverter will
restart work, green light
on, red light off.
Input over
voltage
protection
Green on
Red on
No alarm
No AC output
When the voltage of the
batter return to the related
voltage the inverter will
restart work, green light
on, red light off.
Over load
protection
Green on
Red on
No alarm
No AC output
Reduce the load to
related rang the inverter
will restart work, green
light on, red light off
Over
temperature
shut down
Green on
Red on
Alarm
No AC output
When the inside
temperature return to
related rang, inverter will
restart work, green light
on ,red light off.
Output short
circuit
Green on
Red off
No
Alarm
No AC output
When short circuit
stopped, inverter restart to
work automatically.
(
PS:
:
If with USB port ,the USB port can work normally under all kinds of protection
condition.
)
Ⅶ
. Waste dispose
:
Please do not discard the products when it is useless, otherwise it will cause
environmental pollution.