2.  Please check the voltage carefully before use: 

Inverter’s  input  voltage  must  be  same  as  battery’s  voltage;  appliance’s  working 
voltage must be same as inverter’s output voltage; once all are same, connect them 
in right way based on 

“Connection Explanation”

 of the manual. 

     

3.    Please use the inverter in ventilate condition and make sure the fan is not blocked.   

e. Do not put the inverter under rain or in humid place, keep it dry. In order to keep a 
long lifespan of the inverter, please keep it work under 85% of the related power. 

 

 

    4.    The  inverter  have  input  under  voltage  protect  function,  input  over  voltage  protect 

function, over load protection function, over temperature protect function and short 
circuit protect function. If these happened, the inverter will stop work and after the 
breakdown, the inverter will restart work automatically.   

 
        5.    To save energy, the fan will not work unless the under two situations: 
       

   

 

The  fan  will  work  when  the  load  is  exceed  30%  of  the  related  power  of  the 

inverter; 

 

When the inside temperature of the inverter exceed 60 degree, the fan will work.   

 
        6.    About extended cable using:   
               

 

We do not recommend use extended cable between the inverter and the battery, 

because it will case lost of DC electricity and affect the effect of the inverter.   

 

If really need use extended we suggest you use high quality cable to reduce the 

loss of electricity.   
 

7.    Other matters

 

       

 

This  is  modified  sine  wave  inverter;  When  measuring  the  voltage  please  use 

precise equipment. (RMS) 

         

 

 

 

When  supper  power  to  audio  system,  radio  or  TV,  the  appliance  may  have 

interference and this is normal phenomenon;   

                    When using in cars, please stop use the inverter while the engine stopped

 

                    Please  do  not  open  the  inverter,  if  need  mending  please  ask  professional  to 

mend it. 

 

.    Security matters: 

1.    Please  do  not  operate  the  inverter  while  your  hand  is  wet,  Keep  it  from  the  touch  of 

children.   

2.    The temperature of the shell will be high after longtime working, so do not touch it in 

case scalded; 

3.    Do not put metal into the inverter in case not to electric shock. 

  4.    Do not touch the metal of the socket while insert the plug to the socket of the inverter. 
  5.    Keep the inverter away from explosives;   
  6.    Keep all AC electric away from the inverter, it will damage the inverter and also may   

cause electric shock.   

Summary of Contents for FTS420

Page 1: ...DC TO AC POWER INVERTER FTS420 USER INSTRUCTION MANUAL Applicable for 420W ...

Page 2: ...iciency It owns five protect function such as input under voltage protection input over voltage protection overload protection over temperature protection output short circuit protection These five functions can protect the electrical equipment and the circuit of the vehicle Please read this carefully before using it s applicable to 420W series of products Ⅱ Products and cables diagram AC outlet D...

Page 3: ...ith terminal of the battery and the clip on the black connect with the terminal Do not reverse or it will destroy the power inverter Turn on the power inverter the green light will on Insert the plug of the electric equipment into the AC socket of the inverter Ⅳ Scope of Application and Related Matters 1 Scope of application a Only use for class Ⅱappliance b Scope of electric appliance that inappl...

Page 4: ...exceed 60 degree the fan will work 6 About extended cable using We do not recommend use extended cable between the inverter and the battery because it will case lost of DC electricity and affect the effect of the inverter If really need use extended we suggest you use high quality cable to reduce the loss of electricity 7 Other matters This is modified sine wave inverter When measuring the voltage...

Page 5: ...ter return to the related voltage the inverter will restart work green light on red light off Over load protection Green on Red on No alarm No AC output Reduce the load to related rang the inverter will restart work green light on red light off Over temperature shut down Green on Red on Alarm No AC output When the inside temperature return to related rang inverter will restart work green light on ...

Page 6: ...o load current 0 4A Input under voltage alarm DC 10 2 10 8V Input low voltage shut down DC 9 2 9 8V Input over voltage shut down DC 15 16V Overload shut down 460W 520W Fuse 30A 2 Best working Temperature 5 35 Cooling method Fan Accessories Cigar lighter plug alligator clip cable Technical Assistance If you need technical assistance with your Aerpro inverter now or in the future contact Aerpro Supp...

Reviews: