1.3. Basic Specifications
Table 1-3:
ABL1500-B Series Specifications
Model
ABL1500-B-050
ABL1500-B-100
ABL1500-B-200
Travel
50 mm
100 mm
200 mm
Accuracy
(1)
E1
Calibrated
±0.4 µm
±0.4 µm
±0.7 µm
Standard
±2.0 µm
±4.0 µm
±8.0 µm
E3
Calibrated
±0.3 µm
±0.3 µm
±0.5 µm
Standard
±1.0 µm
±2.0 µm
±5.0 µm
Repeatability
(Bi-Directional)
(1)
E1
±0.15 µm
±0.25 µm
±0.25 µm
E3
±0.15 µm
±0.15 µm
±0.25 µm
Straightness
(1)
±0.25 μm
±0.4 μm
±0.5 μm
Flatness
(1)
±0.25 μm
±0.4 μm
±0.5 μm
Pitch
±0.5 arc sec
±1 arc sec
±2 arc sec
Roll
±0.5 arc sec
±1 arc sec
±2 arc sec
Yaw
±0.5 arc sec
±1 arc sec
±2 arc sec
Maximum Speed
2 m/s
Maximum Acceleration
2 g (No Load)
Maximum Force (Continuous)
93.6 N
Load Capacity
(2)
Horizontal
35 kg
Side
25 kg
Operating Pressure
80 psi ±5 psig
Air Consumption
(3)
24-30 slpm @ 551 kPa
Moving Mass (No Load)
5.9 kg
Stage Mass
19.4 kg
21.0 kg
25.2 kg
Material
Aluminum
Mean Time Between Failure
30,000 Hours
(1) Certified with each stage.
(2) Axis orientation for on-axis loading is listed (refer to
for offset loading behavior).
(3) Air supply must be clean, dry to 0° F dew point and filtered to 0.25 μm or better. Recommend nitrogen at 99.9% purity.
NOTES:
l
Specifications are for single-axis systems measured 25 mm above the tabletop; performance of multi-axis system is payload
and workpoint dependent. Consult the Aerotech factory for multi-axis or non-standard applications.
l
To protect air bearing against under-pressure, an in-line pressure switch tied to the motion controller/amplifier E-Stop is
recommended.
l
Maximum upper axis length is 100 mm when mounting the ABL1500-B in an XY configuration.
www.aerotech.com