background image

 

13

Spa Storage 

Make sure all water is drained from the spa and control box. This is essential to extend the life of 
the spa. We recommend the use of a wet/dry vacuum to blow out or suck up water from the spa 
pipes and pump lines. Remove the filter cartridge. It is recommended you store the spa in its 
original package in a warm dry place. 
 

Note:

 Plastic becomes brittle and susceptible to breakage when exposed to subzero 

temperatures. Freezing can severely damage the spa. Improper winterization of your spa may 
void your warranty.                 

 

DISPOSAL: 

The marking indicates that this product shall not be disposed with the general household waste. 
Please contact your local community about collection points or ask your dealer. This product 
contains valuable materials that can be recycled and contribute to a sustainable environment. 
 

TROUBLE SHOOTING: 

Here are some helpful tips to help you to diagnose and rectify some common sources of trouble. 

 
 

Problem Probable 

causes 

Solutions 

Power pack 

does not 

operate 

-Power failure 
-GFCI tripped 
 

-Check power source 
-Reset GFCI. Check if the homes fixed wiring is 

too thin to afford 1500W 

 

Bubble system 

does not 

operate 

-30 minute auto shut off 

feature activated 

-Air pump is too hot 
 
 

-Press the bubble button to reactivate. 
 
-Unplug the air pump. After the air pump has 
cooled, insert the plug and press the bubble 
button to activate. 
 

Heating system 

does not 

operate 

-Dirty filter cartridge   
-Improper water levels 
-Temperature set too 
low 
 

-Clean or replace the filter cartridge 
-Add water to specified levels. 
-Set to a higher temperature (20-40°C). 
 

Filtering system 

does not 

operate 

-Dirty filter cartridge 
 

-Clean or replace the filter cartridge 
 

Spa leakage 

-Spa is torn or 
punctured 

-Use provided repair patch 

Water not clean 

-Insufficient filtering 
time 
-Dirty filter cartridge   
-Improper water 
maintenance 

-Increase filtration time. 
 
-Clean or replace the filter cartridge. 
-Refer to the chemical manufacturer’s 
instructions. 

Summary of Contents for PH050006

Page 1: ...Owner s Manual Model PH050006 Manufactured By Shanghai Qinxu Plastics Products Co Ltd No 5151 Dongchuan Road Heqing Town Pudong New Area Shanghai CN 201201...

Page 2: ...pply provide a properly located receptacle WARNING No part of the appliance is to be located above the spa pool during use WARNING The electrical plug of the spa should be connected at least 11 5 feet...

Page 3: ...r a healthy adult Lower water temperatures are recommended for young children and when spa use exceeds 10 minutes B Since excessive water temperatures have a high potential for causing fetal damage du...

Page 4: ...spray CAUTION Place only on surface that can withstand the floor loading requirements of your spa SAVE THESE INSTRUCTIONS SPECIFICATIONS Model PH050006 Seating capacity Up to 4 Adults Water capacity 8...

Page 5: ...apable of uniformly supporting this weight for the entire time the spa is installed If the spa is placed on a surface which does not meet these requirements any damage caused by improper support will...

Page 6: ...could damage it and that the location is level so the spa sits stably and properly 2 During filling emptying or when in use water may spill out of the spa Therefore the spa should be installed near a...

Page 7: ...Make sure both are right side up 2 Open the air outlet on the spa located next to the Control Panel Screw one end of the inflation hose onto it 3 Open the air valve on the spa wall Connect the other...

Page 8: ...s in steps 2 5 above accordingly 6 Remove the inflation hose from the air valve on the spa wall and replace the valve cap tightly 7 Remove the inflation hose from the air outlet and replace the outlet...

Page 9: ...re that children cannot use this spa unless they are supervised at all times OPERATION Before operating the spa you must ensure the water level in the spa is at the water level fill line printed on th...

Page 10: ...20 C 68 F to 40 C 104 F 3 After turning off the heating system the filtration system will turn off This is normal But if you press the FILTER on before pressing HEATER on by pressing the HEATER button...

Page 11: ...CI power cord from the electrical receptacle before attempting to clean filter 2 Unscrew the filter cartridge by turning counterclockwise 3 Remove the filter cartridge cover 2 3 4 The filter cartridge...

Page 12: ...ly run in this mode until water stops exiting the inflation hose Never dry run the power pack as such type of operation will void the warranty 4 Once the above steps are completed unscrew the inflatio...

Page 13: ...s to help you to diagnose and rectify some common sources of trouble Problem Probable causes Solutions Power pack does not operate Power failure GFCI tripped Check power source Reset GFCI Check if the...

Page 14: ...ose which can not be negated or limited by law of the state in which the product is used The manufacturer does not authorize or permit any party including its agents distributors or dealers to assume...

Reviews: