7.3 Warranty

Thank you for purchasing this Aeroqual product. To get maximum use of
the features of your new product we recommend that you follow a few
simple steps:

Read the guidelines for safe and efficient use.

Read all the terms and conditions of your Aeroqual Warranty.

Save your original receipt. You will need it for warranty repair
claims. Should your Aeroqual product need warranty service,
you should return it to the dealer from whom it was purchased
or contact Aeroqual.

Our Warranty

Aeroqual warrants this product to be free from defects in material and
workmanship at the time of its original purchase by a consumer, and for
a subsequent period as stated in the following table

:

Products

Warranty Period

Series 130 Controller

One year from the date of purchase

High Ozone Concentration Head

Six months from the date of purchase

Low Ozone Concentration Head

Six months from the date of purchase

All accessories for the product are covered by a warranty for a period as
follows

:

Accessories

Warranty Period

Other Accessories

One year from the date of purchase

This warranty is expressly limited to the original owner who purchases
the equipment directly from Aeroqual or from an authorized Aeroqual
dealer.

What we will do

If, during the warranty period, this product fails to operate under normal
use and service, due to improper materials or workmanship, Aeroqual
subsidiaries, authorized distributors or authorized service partners will, at
their option, either repair or replace the product in accordance with the
terms and conditions stipulated herein.

Conditions

1.

The warranty is valid only if the original receipt issued to the original purchaser by
the dealer, specifying the date of purchase, is presented with the product to be
repaired or replaced. Aeroqual reserves the right to refuse warranty service if this
information has been removed or changed after the original purchase of the
product from the dealer.

2.

If Aeroqual repairs or replaces the product, the repaired or replaced product shall
be warranted for the remaining time of the original warranty period or for ninety
(90) days from the date of repair, whichever is longer. Repair or replacement may
be via functionally equivalent reconditioned units. Replaced faulty parts or
components will become the property of Aeroqual.

3.

This warranty does not cover any failure of the product due to normal wear and
tear, damage, misuse, including but not limited to use in any other than the normal
and customary manner, in accordance with Aeroqual’s user guide for use, faulty
installation, calibration and maintenance of the product, accident, modification or
adjustment, events beyond human control, improper ventilation and damage
resulting from liquid or corrosion.

4.

This warranty does not cover product failures due to repairs, modifications or
improper service performed by a non-Aeroqual authorized service workshop or
opening of the product by non-Aeroqual authorized persons.

5.

The warranty does not cover product failures which have been caused by use of
non-Aeroqual original accessories.

6.

Tampering with any part of the product will void the warranty.

7.

Damage to the sensors can occur through exposure to certain sensor poisons
such as silicones, tetraethyl lead, paints and adhesives. Use of Aeroqual sensors
in these environments containing these materials may (at the discretion of
Aeroqual) void the warranty on the sensor head. Exposure to levels of ozone
outside of the design range of a specific Aeroqual sensor head can adversely
affect the calibration of that sensor head and will also void this warranty as it
applies to the replacement of sensor heads.

8.

Aeroqual makes no other express warranties, whether written or oral, other than
contained within this printed limited warranty. To the fullest extent allowable by law
all warranties implied by law, including without limitation the implied warranties of
merchantability and fitness for a particular purpose, are expressly excluded, and in
no event shall Aeroqual be liable for incidental or consequential damages of any
nature whatsoever, however they arise, from the purchase or use of the product,
and including but not limited to lost profits or business loss.

Some countries restrict or do not allow the exclusion or limitation of incidental or
consequential damage, or limitation of the duration of implied warranties, so the
preceding limitations or exclusions may not apply to you. This warranty gives you
specific legal rights, and you may also have other rights, which may vary from
country to country.

14

15

Summary of Contents for 130 Series

Page 1: ...atement of Compliance 13 7 3 Warranty 14 7 4 Guidelines on How to Measure Ozone 16 Version 1 1 20 02 10 1 0 Ozone Controller Components Series 130 Ozone Controller The following components are supplied with the Series 130 Ozone Controller Series 130 controller assembly inside an FRP enclosure Ozone sensor head plugged in User guide Wall fixing brackets Eight pole M12 male cable connector Please ch...

Page 2: ...e powered by a 24VDC power supply user supplied The permissible voltage range is between 16VDC and 28VDC Ensure that the power supply to the unit is sized to account for the voltage drop across the connecting cable so that it delivers at least 16VDC minimum to the Series 130 The unit does not have an On Off switch and is activated when power is supplied to the unit Before powering up the unit ensu...

Page 3: ...igh Low conc B1 High Limit Control Alarm B2 Low Limit 3 3 Operating as a Controller Set the mode dip switch B 2 to position off Set the low C and high A control limits dead band by configuring the dip switches as per the dip switch table on page 8 When in control mode relay 1 operates as per the table and diagram below Relay 2 is opposite Controller mode LED Relay and Status Ozone LED Relay 1 Rela...

Page 4: ...re available Ozone LED Relay 1 Relay 2 below low limit GREEN open open between low and high limits ORANGE closed open above high limit RED closed closed Sensor fault RED FLASH open open Settings fault ORANGE FLASH open open LED Color Meaning Controller Mode Green 2 sec flashing Warm up 10 minute cycle Orange Below low setpoint Green Between low and high setpoint Red Above high setpoint Dual Alarm ...

Page 5: ...Volt free contacts Max voltage 28V Max current 150mA Power Requirements 24 VDC Enclosure size see page 10 180mmL x 110 mmW x 90mmD enclosure only 230mmL x 110mmW x 90mmD including nozzles 8 9 High Setpoint Dipswitch Setpoints 1 2 3 4 Low Sensor ppm High Sensor ppm off off off off 0 000 0 000 on off off off 0 020 0 200 off on off off 0 030 0 400 on on off off 0 040 0 600 off off on off 0 050 0 800 ...

Page 6: ...ensor Span calibrate sensor Check calibration of gas generator Move sensor to clean air and check reading upon exposure to known gas concentration Replace refurbish sensor Sensor output noisy Power supply noise Local air flow too high Environmental conditions fluctuating Install regulated power supply Reduce air flow Reduce fluctuations Sensor showing lower than expected reading in the presence of...

Page 7: ...7 2 Statement of Compliance 1 The Aeroqual Series 130 Ozone Monitors comply with EN 55022 1998 2 The Aeroqual Series 130 Ozone Monitors comply with EN 61000 6 1 2001 3 The Aeroqual Series 130 Ozone Controller complies with Part 15 of the FCC Rules Operation is subject to the following two conditions i these devices may not cause harmful interference and ii these devices must accept any interferenc...

Page 8: ...may be via functionally equivalent reconditioned units Replaced faulty parts or components will become the property of Aeroqual 3 This warranty does not cover any failure of the product due to normal wear and tear damage misuse including but not limited to use in any other than the normal and customary manner in accordance with Aeroqual s user guide for use faulty installation calibration and main...

Page 9: ... ozone The controller must not be placed directly in an ozone stream For indoor local area monitoring attach the controller to an inert surface such with the inlet unobstructed For leak detection mount the unit near the ozone equipment Ensure that the controller is protected from excessive water splashing dust vibration excessive heat or cold high concentrations of ozone and excessive swings in hu...