4. INSTALLATION:
4-1. MOUNTING:
Each
SmartStep
Interface is supplied with four 4-40 UNC-2B mounting holes located on bottom
side of the housing. Screw penetration into housing is 3/16" maximum. See paragraph 3 for mounting location.
4-2 CONFIGURING THE 8210A-2-5 HARDWARE:
Figure 2 and the following steps are provided as a guideline in
connecting up the Model 8210A-2-5 and its associated system components.
Figure 2. Sample Interconnection Diagram
a. Setup the RS-232/422/485 Communications options for your application using paragraph 5-1 and
Figure 3.
b. Connect the desired controller to the Model 8210A-2-5-X’s bus connector. For specific connector details
reference the following:
Model Bus Type Paragraph
8210A-2-5-2
RS-232
5-3
8210A-2-5-2
RS-422/485
5-4
c. Using the interconnect cable (P/N 193-8013) supplied with the Model 8210A-2-5, connect the
SmartStep
Attenuator or other device to the Model 8210A-2-5’s Driver Interface connector. For specific Device
Interface connector details, refer to paragraph 6-2. Refer to paragraph 7 to order additional interface
cables and other accessories for connecting multiple attenuators or other devices to the 8210A-2-5.
d. Connect a +5 V Power Supply to the Model 8210A-2-5’s DC IN +5V Input Connector which is located on
the Model 8210A-2-5 front panel (Figure 1), is a standard 2.5mm barrel style DC jack. Refer to
specifications for exact power requirements.
Summary of Contents for 8210A-2-5