2-39
C. Receiver
Calibration
TEST EQUIPMENT:
Power Meter
Power Meter Sensor
Power Splitter (2-Way Resistive)
1.
With the System Menu displayed, press the F4 “Selftest” Key to display the Self Test
Menu.
2.
Press the 3 Key to display the Calibration Screen.
3.
Enter the Calibration Password (
30203
). Press the F1 “Done” Key to display the Internal
Calibration Menu.
4.
Press the 8 Key (REC CAL AUTO) to display the Receiver Calibration Screen.
5.
With the cursor on the Mode field, set the Mode selection based on the Power Meter used:
AUTO
Agilent N1911A Power Meter / Agilent E4412 Power Sensor
MANUAL
Other Power Meter / Power Meter Sensor.
ANT
CONNECTOR
6.
Establish the following test setup:
SW R
ANT
Te st
*
Se t
Pow e r
*
Me te r
Channel
*
A
Ethe rne t
(
*
On ly
*
r eq u ir ed
*
f o r
*
AU T O
*
M o d e
*
)
Pow e r
*
Me te r
*
Se nsor
Pow e r
Splitte r
7.
Press the F3 “CAL” Key.
8.
Press the F1 “ANT” Key and follow the instructions on the screen to calibrate the UUT ANT
Port.
In MANUAL Mode the Test Set prompts the user to enter readings from the Power Meter.
NOTE
This is an interactive process. At each frequency the output level is
adjusted based upon the Power Meter reading entered by the user until
the reading is within acceptable limits.
Summary of Contents for 3500A
Page 4: ...Subject to Export Control see Cover Page for details THIS PAGE INTENTIONALLY LEFT BLANK...
Page 22: ...1 12 Subject to Export Control see Cover Page for details THIS PAGE INTENTIONALLY LEFT BLANK...
Page 24: ...THIS PAGE INTENTIONALLY LEFT BLANK Subject to Export Control see Cover Page for details 1 14...
Page 38: ...2 14 Subject to Export Control see Cover Page for details THIS PAGE INTENTIONALLY LEFT BLANK...
Page 76: ...2 52 Subject to Export Control see Cover Page for details THIS PAGE INTENTIONALLY LEFT BLANK...
Page 116: ...2 92 Subject to Export Control see Cover Page for details THIS PAGE INTENTIONALLY LEFT BLANK...
Page 122: ...A 6 Subject to Export Control see Cover Page for details THIS PAGE INTENTIONALLY LEFT BLANK...
Page 144: ...B 10 Subject to Export Control see Cover Page for details THIS PAGE INTENTIONALLY LEFT BLANK...
Page 146: ...C 2 Subject to Export Control see Cover Page for details THIS PAGE INTENTIONALLY LEFT BLANK...
Page 150: ...E 2 Subject to Export Control see Cover Page for details THIS PAGE INTENTIONALLY LEFT BLANK...
Page 166: ...THIS PAGE INTENTIONALLY LEFT BLANK Subject to Export Control see Cover Page for details E 18...