Compact
FLAT
SN 2 Mounting Gauge
7
Positioning the feet - SN 2 Plus
Mount the first three feet (1-3) according to the mounting instructions.
The correct spacing dimensions of the feet must be taken from the planning documents.
Place the mounting gauge according to the illustration and fix the spacer (distance A = 50 mm).
The adjusted mounting gauge can now be repositioned, turning the mounting gauge 180° and placing it on the opposite
side, leaving the two spacers (2) and (3) between the two rear feet (see illustration).
Depending on the type of clamp, the relevant spacer (1) must be selected:
Short-side clamping: B = 31 mm
Long-side clamping: B = 23 mm
Position the front feet on both sides of the spacer (1) and fix them in place.
The mounting gauge is now set for the SN 2 Plus System and can be used as a gauge for the project.