aero pure VSF110DH-S Installation Manual Download Page 4

 
Install ceiling material to complete the ceiling construction. Then, cut around 
the fan housing. 
To attach the grille assembly to the fan housing, pinch the grille springs on 
the sides of the grille assembly, and position the grille into the housing 
with the grille springs in the appropriate slots. Gently push the grille 
assembly towards the ceiling to secure. 
 

SERVICE PARTS

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

* Blower Assembly includes part 

6, 5, d, 4, c, b, a.

Replacement installation:   
Remove the screw (part c), then take out the motor plate (part 3) from   
the housing (part 9) by pushing down the rib in the plate while pulling 
out on the side of the housing. Replace the broken parts. 
WARNING: Before replacing, be sure to turn off power at power source. 
 

WARRANTY 

This warranty covers all defects in workmanship or materials for: 
The mechanical and electrical parts contained in this product for a period of 72 months from the date of purchase. You must keep 
and be able to provide your original sales receipt as proof of date of purchase. This warranty is covered to the original retail 
purchaser of this product only. The manufacturer will replace any mechanical or electrical part that proves defective in normal 
household use for a period of 72 months. 
THIS WARRANTY DOES NOT COVER: 

  Damages from improper installation. 

  Damages from shipping 

  Damages from misuse, abuse, accident, alternation, lack of proper care and maintenance. 

  Damages from service by persons other than a licensed electrician. 

  Does not cover any labor or transportation charges related to the repair of this product. 

  Does not cover any fans/products purchased as USED or from a non-authorized seller of Aero Pure Fans. 

THIS LIMITED WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING THE 
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. 
 
The remedy provided in this warranty is exclusive and is granted in lieu of all other remedies. This warranty does not cover incidental 
or consequential damages. Some states do not allow the exclusion of incidental or consequential damages, so this limitation may not 
apply to you. 
Some states do not allow limitations on how long an implied warranty lasts, so this limitation may not apply to you. This warranty 
gives you specific legal rights; you may also have other rights, which vary from state to state. 

 
                                              READ AND SAVE THESE INSTRUCTIONS 
                                          Installer: Leave this manual with the homeowner 

                                                                                                                  4 
                                                                                                                                                                                                 

Aero Pure VSF110DH-S

 

PART

 

PART NAME

 

Qty.

 

Grille Assembly (includes part 2)

 

Grille Spring

 

Power box

 

Motor Plate

 

Motor

 

Blower Wheel

 

Wire Panel / Harness Assembly

 

Hanger Bar Kit (long)

 

Wiring plate

 

10 

Housing

 

11 

Damper / Duct    Connector 

 

 

Nut, Hex Lock

 

Washer

 

Screw

 

Isolator

 

Screw

 

Summary of Contents for VSF110DH-S

Page 1: ...2 5 m 8 feet above the floor 12 WARNING To reduce the risk of fire or electric shock do not use this fan with any solid state speed control device 13 The fan must not be installed in a ceiling thermally insulated to a value greater than R40 CAUTION 1 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 2 This product is designed for installation in cei...

Page 2: ...ward maximum If the control is responding too often to changing environmental conditions movement toward less H may be required To adjust the H 1 Disconnect power at service entrance 2 Through the grille locate the slot marked H 3 Carefully rotate the H adjustment toward or 4 Turn on power and check operation by turning on the shower or other humidity source until the fan turns on 5 Repeat above s...

Page 3: ...g Hold housing in place so that the housing contacts the bottom of the joist Screw housing to joist through hole A and hole B Screw the hangar bar onto the other side of joist through the hole refer to diagram at right Screw hanger bar to housing with screw A 5 INSTALL DUCTWORK Connect the round ductwork not included to the damper duct connector and run the ductwork to a roof or wall cap not inclu...

Page 4: ... installation Damages from shipping Damages from misuse abuse accident alternation lack of proper care and maintenance Damages from service by persons other than a licensed electrician Does not cover any labor or transportation charges related to the repair of this product Does not cover any fans products purchased as USED or from a non authorized seller of Aero Pure Fans THIS LIMITED WARRANTY IS ...