aero pure VSF110DH-S Installation Manual Download Page 2

 

OPERATION 

 

HUMIDITY SENSOR OPERATION

 

The humidity-sensing fan uses a sophisticated humidity sensor that responds to:   
(a) rapid to moderate (user-adjustable) increases in humidity or (b) humidity above a   
user-adjustable set-point (50%-100% relative humidity). 

If the fan continuously responds   

to changing environmental 

conditions,“H” (means “humidity”) adjustment may be 

required. 

This feature is factory-set for about 75% (Ambient temperature of 77F).

   

 
 

SENSITIVITY ADJUSTMENT 

The “H” has been factory set for most shower applications. 

However, if the fan is in a tub area or is being used for dampness

 

control, the “H” may need to be increased toward maximum “+”.

 If the control is responding too often to changing 

environmental conditions, movement toward less “-” “H” may be required. 
To adjust the “H”: 
1. Disconnect power at service entrance. 
2. Through the grille, locate the slot marked “H”. 
3. Carefully rotate the “H” adjustment toward “+” or “-”. 
4. Turn on power and check operation by turning on the shower or other humidity source until the fan turns on. 
5. Repeat above steps if necessary. 
When the temperature changes, humidity sensor values will have deviation. 

 
 
 
PLAN THE INSTALLATION 

             
    1. Do not use in a cooking area.                                      2. Two ways to connect ductwork to a factory-shipped unit 
 
 
 
 
 
 
 
 
 
 
 
 

ASSEMBLY INSTRUCTIONS 

1. Before installation, you need to know: 
 
 
 
 
 
 
 
 
 
 
 
 

Note: Hanger bar short only can slide into channel A. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

READ AND SAVE THESE INSTRUCTIONS 

Installer: Leave this manual with the homeowner 

Aero Pure VSF110DH-S

 

Summary of Contents for VSF110DH-S

Page 1: ...2 5 m 8 feet above the floor 12 WARNING To reduce the risk of fire or electric shock do not use this fan with any solid state speed control device 13 The fan must not be installed in a ceiling thermally insulated to a value greater than R40 CAUTION 1 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 2 This product is designed for installation in cei...

Page 2: ...ward maximum If the control is responding too often to changing environmental conditions movement toward less H may be required To adjust the H 1 Disconnect power at service entrance 2 Through the grille locate the slot marked H 3 Carefully rotate the H adjustment toward or 4 Turn on power and check operation by turning on the shower or other humidity source until the fan turns on 5 Repeat above s...

Page 3: ...g Hold housing in place so that the housing contacts the bottom of the joist Screw housing to joist through hole A and hole B Screw the hangar bar onto the other side of joist through the hole refer to diagram at right Screw hanger bar to housing with screw A 5 INSTALL DUCTWORK Connect the round ductwork not included to the damper duct connector and run the ductwork to a roof or wall cap not inclu...

Page 4: ... installation Damages from shipping Damages from misuse abuse accident alternation lack of proper care and maintenance Damages from service by persons other than a licensed electrician Does not cover any labor or transportation charges related to the repair of this product Does not cover any fans products purchased as USED or from a non authorized seller of Aero Pure Fans THIS LIMITED WARRANTY IS ...