AERMEC VES Instruction Manual Download Page 5

19

C/F

C

VC/F

VC

C/F

C

VC/F

VC

SA

VC/F

VC

SA

VC/F

SA

C/F

VC/F

SA

C/F

SA

C/F

SA

SW

VC/F

VC

SA

SW

VC/F

VC

SA

C/F

C

SW

VC/F

C/F

VC/F

SA

SW

C/F

SA

SW

C/F

SW

2 pipe system with water sensor

SW

 

Water temperature sensor

VC/F

 

Valve (Heat / Cool)

VC

 Valve 

(Heat) 

SA

  

Ambient temperature sensor

C/F

 Coil 

(Heat / Cool)

C

 Coil 

(Heat)

SYSTEM EXAMPLES

2 pipe system without water sensor

4 pipe system with water sensor

4 pipe system without water sensor

Legend:

MAIN COMPONENTS 

1

 Discharge  air

2

 Frame

3

 Vent / drain on coil

4

 Hydraulic connections (water outlet)

5

 Mounting  slot

Holes for heat exchanger coil

7

 Hydraulic connections (water inlet)

  Water discharge of exchanger coil

9

 Condensate  discharge

10 

Left side (load bearing

11 

Front panel enclosure (lower)

12 

Filter lock

13

 Condensate drain tray

14

 Electric motor 

15

 Electrical box of electric motor 

16

 Centrifugal fan

17

 Air filter (intake)

18 

Electrical box

19 

Exchanger coil

20

 Right side (load bearing)

21

 Discharge air flange

VES 030

VES 040

VES 130

VES 140

VES 230

VES 240

VES 330

VES 340

2

3

1

4

6

17

13

11

14 15

16

10

11

5

7

8

9

18

19

12

5

20

21

Summary of Contents for VES

Page 1: ...lazione FAN COIL FOR HORIZONTAL AND VERTICAL DUCTED INSTALLATION Ͳ ŶƐƚĂůůĂƟŽŶ DĂŶƵĂů s Ed Kͳ KEs d hZ WKhZ E d d KE E KZ KEd ET VERTICALE Ͳ DĂŶƵĞů Ě ŝŶƐƚĂůůĂƟŽŶ GEBLÄSEKONVEKTOR FÜR KANAL HORIZONTAL UND VERTIKALEINBAU Ͳ ŶƐƚĂůůĂƟŽŶƐĂŶůĞŝƚƵŶŐ FAN COIL PARA INSTALACIÓN CANALIZADA HORIZONTAL Y VERTICAL Manual de instalación IT GB FR DE ES pag 6 pag 16 pag 26 pag 36 pag 46 ...

Page 2: ...uous speed modulation divided into zones up to 64 the circulating pumps up to 12 and the heat recovery units with air quality sensors up to 3 optimising the performance in air conditioning and heating ensuring comfort and energy savings INDEX Important information Maintenance Packaging Use 17 Unit Description Versions 18 System examples Main components 19 Component description 20 Operating limits ...

Page 3: ...gh occupancy or requiring elevated hygiene standards DURING OPERATION Always leave the filter in the fan coil unit during operation otherwise dust in the air will dirty the surfaces of the coil WHAT IS NORMAL During cooling water vapour may be present in the air discharge During heating it might be possible to hear a slight hiss around the fan coil unit Sometimes the fan coil unit might give off u...

Page 4: ...installation into the VMF system Wide possibility of different available static pressures Versions with 6 speed fan motor from which the preferred 3 are selected Versions with 7 speed fan motor from which the preferred 3 are selected Centrifugal fan designed for low noise levels G3 class filter Air intake filter easily extracted for periodic cleaning 3 way 4 port valve accessory 2 way valve access...

Page 5: ...end MAIN COMPONENTS 1Discharge air 2Frame 3Vent drain on coil 4Hydraulic connections water outlet 5Mounting slot 6Holes for heat exchanger coil 7Hydraulic connections water inlet 8 Water discharge of exchanger coil 9Condensate discharge 10 Left side load bearing 11 Front panel enclosure lower 12 Filter lock 13Condensate drain tray 14Electric motor 15Electrical box of electric motor 16Centrifugal f...

Page 6: ...s HYDRAULIC CONNECTIONS The female hydraulic connections are located on the left side The coil can be rotated on site to move the connections to the right side CONTROL PANEL Various control panels are available to suit the installation Combining the control panels the thermostats and the other VMF system accessories fully exploits the potential of the VES units The VMF system thermostats allow Con...

Page 7: ... might form on the air discharge and unit casing This condensate might be deposited on the floor and on any objects underneath To prevent the formation of condensation on the exterior of the unit while the fan is operating the average water temperature should not drop below the operating limits shown in the table below determined by the room ambient conditions These limits refer to unit operation ...

Page 8: ...minimum temperature water sensor can be installed in two positions in its mount in the coil to the flow tube upstream of the valve Refer to the thermostat manual before selecting the position of the minimum temperature water sensor as a function of the preferred control logic The thermostat may require changes to the dip switch internal settings WARNING After completing the installation check the ...

Page 9: ...densate drain connection on the side of the hydraulic connections For horizontal installations mount the condensate discharge drain connection provided loose Care should be taken to seal the fitting between the drain pan and the drain connection with silicone sealant Seal the drain not used Connect the drain pan fitting to the condensate drain system Use a drain tube that must be connected to the ...

Page 10: ...lectrical wiring diagrams are subject to constant updates Always refer to the wiring diagrams inside the unit The control panel cannot be mounted on a metallic wall unless this is permanently earthed Carefully read the instructions before installing the control panel and if necessary proceed with the configuration of the panel Some controls panels require connection to other components supplied as...

Page 11: ...closed with insulating material refit the cover 4 and fix with the screws mount the plastic caps 7 supplied loose into the holes left empty by the hydraulic connections all the drain pans are provided with condensate discharg es on both sides remove the electrical connections from the right side remove the knock out and move the grommet 9 from right to left move the electrical connections to the l...

Page 12: ...l e a s e r e f e r t o t h e o n e s s u p p l i e d w i t h t h e u n i t Nos schémas électriques étant constamment mis à jour il faut absolument se référer à ceux fournis à bord de nos appareils Die Schaltpläne werden ständig aktualisiert deswegen muss man sich stets auf das mit dem Gerät gelieferte Schaltschema beziehen El cableado de las máquinas es sometido a actualizaciones constantes Por f...

Reviews: