AERMEC UFB Series Use And Installation  Manual Download Page 6

6

IUFBTY 1503 -

 

5495900_00

15.  IMPORTANT INFORMATION AND MAINTENANCE

  WARNING:  The  unit  is  connected  to 

the  power  supply  network  circuit.  Any 
intervention by personnel not technically 
qualified  can  result  in  injury  to  the 
operator and damage to the unit and the 
surrounding environment. 

ONLY PROVIDE A POWER SUPPLY OF  

220-

230V   50/60Hz TO THE UNIT

Using other power supply ratings can cause 

irreparable damage to the unit. 

DO NOT USE THE UNIT IMPROPERLY

Do not use the unit in animal husbandry 

applications.

VENTILATING THE ROOM

Periodically air the room in which the unit 

has been installed; this is particularly 
important if the room is occupied by 
many people, or if gas appliances or 
sources of odours are present.

C O R R E C T LY   C O N T R O L L I N G   T H E 

TEMPERATURE

The room temperature should be 

controlled in order to provide maximum 
comfort to the people in the room, 
especially if they are elderly, children 
or ill, avoiding sudden changes in 
temperature between the outside and 
inside above 7 °C in summer. 

A too low temperature will lead to 

increased electrical consumption in the 
summer.

CORRECTLY ADJUSTING THE AIR JET

The air coming out of the unit must not 

strike people directly; in fact, even if at 
a temperature that is higher than the 
room temperature, it could cause a cold 
sensation and resulting discomfort. 

ORDINARY MAINTENANCE 

The ordinary maintenance can be carried 

out by the user and consists of a series of 
simple operations, which will ensure that 
the unit operates at full efficiency.

Visual inspection of the state of the unit for 

every maintenance operation; any fault 
must be communicated to the After-Sales 
Service.

EXTERNAL CLEANING 

- External weekly cleaning, to be done with 

a damp cloth (soaked in water no hotter 
than 40 °C) and a neutral detergent: avoid 
using any other type of detergent or 
solvent.

- Do not splash water on interior or exterior 

surfaces of the unit (it could cause short 
circuits). 

PERIODIC FILTER CLEANING

Frequent filter cleaning ensures a better 

operating efficiency.  

Check if the filter is very dirty: in this case 

increase the cleaning frequency. 

Clean frequently by removing the 

accumulated dust with a vacuum cleaner.

When the filter is clean refit it to the unit 

reversing the removal procedure. 

SPECIAL CLEANING

The possibility of removing the unit 

inspection panels (carried out only by 
personnel suitably qualified) allows detailed 
cleaning of the internal parts, particularly 
for installations with high occupancy or 
requiring elevated hygiene standards. 

DURING OPERATION

Always leave the appropriate screw locking 

for the for filter in the unit during operation 
otherwise dust in the air will dirty the 
surfaces of the coil. 

WHAT IS NORMAL

During cooling, water vapour may be 

present in the air discharge.

During heating it might be possible to hear 

a slight hiss around the unit. Sometimes 
the unit might give off unpleasant smells 
due to the accumulation of substances 
from the air of the room (especially if the 

room is not ventilated regularly. Clean the 
filter more often).

During operation, there could be noises 

and creaks inside the unit, due to the 
thermal expansion of the various 
components (plastic and metallic), but 
this does not indicate a malfunction and 
does not cause damage to the unit. 

OPERATING FAULTS

In the event of an operating fault disconnect 

and  reconnect  power  to  the  unit  and 
proceed with restarting the device. 

WARNING! Do not attempt to repair the unit 

as this is very dangerous!

If the problems persists immediately call the 

local After-Sales Service.

DO NOT PULL THE ELECTRICAL CABLE

It is very dangerous to pull, tread on or 

crush the electrical power cable or fix it 
with nails or drawing pins.

A damaged power cable can cause short 

circuits and personal injury.

DO NOT PUT ANYTHING IN THE AIR 

OUTLET

Do not put anything at all in the air outlet 

slots.

This could cause injury to people and damage 

to the fan. 

WARNING

This appliance can be used by children 

aged from 8 years and above and persons 
with reduced physical, sensory or mental 
capabilities or lack of experience and 
knowledge if they have been given 
supervision or instruction concerning 
use of the appliance in a safe way and 
understand the hazards involved. 
Children shall not play with the appliance. 
Cleaning and user maintenance shall not 
be made by children without supervision

16.  FILTER MAINTENANCE AND CLEANING

Summary of Contents for UFB Series

Page 1: ...USE AND INSTALLATION MANUAL EN installation Underfloor air Conditioning System UFB 220 230V 50 60Hz IUFBTY 1503 5495900_00 ...

Page 2: ...2 IUFBTY 1503 5495900_00 ...

Page 3: ...nte es conforme conla legislación de armonización pertinente de la Unión CEI EN60335 2 80 2005 CEI EN60335 2 80 A2 2009 CEI EN55014 1 2008 CEI EN55014 2 1998 CEI EN61000 6 1 2007 CEI EN61000 6 3 2007 Soddisfacendo così i requisiti essenziali delle seguenti direttive Thus meeting the essential requisites of the following directives Satisfaisant ainsi auxconditions essentielles des directives suivan...

Page 4: ...in use INDEX 1 GENERAL WARNINGS 20 2 PRODUCT IDENTIFICATION 20 3 IMPORTANT INFORMATION AND MAINTENANCE 21 4 FILTER MAINTENANCE AND CLEANING 21 5 FEATURES 22 6 OPERATION 23 7 MAIN COMPONENTS HE VERSION 23 8 TECHNICAL DATA 24 9 DIMENSIONS AND WEIGHT 24 10 INSTALLATION OF THE UNIT 25 11 ELECTRICAL CONNECTIONS AND CONTROLS 25 12 WIRING DIAGRAM 26 ...

Page 5: ...NDARDS The unit must be installed by a com petent and qualified technician and in accordance with the legislation ap plicable in the country of installation Aermec assumes no responsibility for damage caused by failure to observe these instructions Instructions essential for the proper in stallation of the equipment are shown here The final details to all the opera tions are left to the experience...

Page 6: ...aning frequency Clean frequently by removing the accumulated dust with a vacuum cleaner When the filter is clean refit it to the unit reversing the removal procedure SPECIAL CLEANING The possibility of removing the unit inspection panels carried out only by personnel suitably qualified allows detailed cleaning of the internal parts particularly for installations with high occupancy or requiring el...

Page 7: ... UFB20 Damper is manufactured in galvanized steel and connected to a synchronous motor controlled by the microprocessor control board The UFB20 fan is a centrifugal fan with a continuously variable EC motor The fan propeller and the fan shell are manufactured in antistatic plastic material The UFB20 has as standard a pre charged electrostatic filters This filter attracts and retains all suspended ...

Page 8: ...ovide the fresh air requirements for the space HEATING MODE If the room sensor detects that the local temperature is too cold it interrogates the underfloor sensor If the underfloor temperature is above that of the room air the damper is modulated open to allow heating to the space The damper is modulated sufficiently to offset the heat loss to the space Mixed Air Discharge Under floor Air Suction ...

Page 9: ...0 mm 64 70 mm 219 19 mm 569 82 mm size 20 Weight kg UFB 15 5 UFB_EW 17 21 TECHNICAL DATA Mod UFB 20 FEATURES Fan Motor Type Brushless Motor Fan speed Type Continuous fan speed regulation Casing thickness mm 1 Max fan power input W 58 Max fan power input for UFB_EH W 540 Air flow rate m3 h 100 650 ...

Page 10: ... 1503 5495900_00 22 ELECTRICAL CONNECTIONS AND CONTROLS ON OFF Selector Switch Temperature Adjustement Switch 23 INSTALLATION OF THE UNIT length of the supply cable 5m Predisposition of the supporting structure ...

Page 11: ...11 IUFBTY 1503 5495900_00 24 WIRING DIAGRAM 220 230V 50 60Hz 4102100_01 ...

Page 12: ......

Page 13: ...13 IUFBTY 1503 5495900_00 ...

Page 14: ......

Page 15: ...15 IUFBTY 1503 5495900_00 ...

Page 16: ...nding Aermec S p A shall have the right to introduce at any time whatever modifications deemed necessary to the improve ment of the product AERMEC S p A 37040 Bevilacqua VR Italia Via Roma 996 Tel 39 0442 633111 Telefax 39 0442 93577 www aermec com ...