FCXI 20 / 220 US
FCXI 30 / 220 US
FCXI 40 / 220 US
FCXI 50 / 220 US
FCXI 80 / 220 US

FCXI 24 / 220 US
FCXI 34 / 220 US
FCXI 44 / 220 US
FCXI 54 / 220 US
FCXI 84 / 220 US

FAN COIL WITH INVERTER
VENTILO-CONVECTEUR AVEC INVERTER

U S E   A N D   I N S T A L L A T I O N   M A N U A L
MANUEL D’UTILISATION ET D’INSTALLATION

IFCXIUSLJ 1203 - 5383620_00

FCXI US

Summary of Contents for FCXI 20 / 220 US

Page 1: ...XI 80 220 US FCXI 24 220 US FCXI 34 220 US FCXI 44 220 US FCXI 54 220 US FCXI 84 220 US FAN COIL WITH INVERTER VENTILO CONVECTEUR AVEC INVERTER U S E A N D I N S TA L L AT I O N M A N UA L MANUEL D UT...

Page 2: ......

Page 3: ...ation de l unit Raccords hydrauliques Raccords d vacuation des condensats 16 Raccordements lectriques Rotation de la batterie 17 Dimensions 18 Schemas electriques 23 Solution des problemes 24 R glages...

Page 4: ...not in any case cover costs due to automatic ladders scaffolding or other lifting systems neces sary for carrying out repairs under guarantee AERMEC S p A declines all responsibility for any damage wh...

Page 5: ...order SUPPLEMENTARY CLEANING The fact that the blades of examinable shrouds can be removed operation done only by adequately skilled technicians ensures a thorough cleaning of the internal components...

Page 6: ...total input power is determined by adding the input power for the unit and the input power for the accessories connected and declared in the corresponding manuals OPERATING LIMITS FCXI 20 220US 30 220...

Page 7: ...nate current motors the brushless electric motor offers huge advantages Reduced wear and tear The possibility to regulate the rotation speed in a precise continuous manner 0 100 Higher energy yields L...

Page 8: ...he oil vapours mixed with the treated air can be deposited on the exchange coils reducing their performance or on the parts inside the unit damaging the plastic parts If a three way valve is installed...

Page 9: ...he relative chapter The fan coils that work in heat mode only do not require condensate discharge Make the electrical wiring as shown in the relative chapter and in the wiring diagrams Install and con...

Page 10: ...th a minimum contact opening distance of 0 12inch 3mm The use of B type circuit breakers is recommended For installations with three phase power supply the following precautions should be considered 1...

Page 11: ...1 97 1 97 1 97 1 97 Weight Poids lbs 33 07 34 17 44 09 45 19 52 91 54 01 52 91 54 01 74 96 75 06 Metric system Syst me m trique A mm 487 487 487 487 590 B mm 750 980 1200 1200 1320 C mm 220 220 220 2...

Page 12: ...21 97 C 1 97 1 97 B A 35 x 0 79 15 28 8 50 1 61 3 98 1 93 5 67 1 77 3 35 1 18 1 18 8 50 3 78 2 36 7 76 17 83 17 83 0 98 FCXI 20 30 40 50 220US FCXI 24 34 44 54 220US FCXI 80 US FCXI 84 US 3 R 4 R 3 R...

Page 13: ...8 B mm 522 753 973 1122 1122 C mm 440 671 891 891 1102 FCXI 20 30 40 50 220US FCXI 24 34 44 54 220US FCXI 80 220US FCXI 84 220US 3 R 4 R 3 R 1 R 3 R 4 R 3 R 1 R Metric system Syst me m trique FCXI 20...

Page 14: ...ie femelle 3 4 F 3 4 F 3 4 F 3 4 F 3 4 F FCXI 20 220US 30 220US 40 220US 50 220US 80 220US 24 220US 34 220US 44 220US 54 220US 84 220US US measure system Syst me de mesure US inches A 15 91 15 91 15 9...

Page 15: ...S 30 220US 40 220US 50 220US 80 220US BV1 BV1 BV1 BV1 BV1 US measure system Syst me de mesure US inches A 16 06 16 06 16 06 16 06 20 43 B 12 72 12 72 12 72 12 72 14 88 C 6 02 6 02 6 02 6 02 6 69 D 3 7...

Page 16: ...ng Raccordements effectuer in situ AR Orange Orange BI White Blanc BL Blue Bleu GI Yellow Jaune GR Grey Gris MA Brown Marron NE Black Noir RO Red Rouge VE Green Vert VI Violet Violet READING KEY LEGEN...

Page 17: ...ure and humidity indica ted in MINIMUM AVERAGE WATER TEMPERATURE have been reached On a atteint les conditions limite de temp rature et d humidit indiqu es dans TEMPERATURE MINIMA LE MOYENNE DE L EAU...

Page 18: ...FCXI84 220US WARNING Do not modify the unit s settings Any change to the inverter card dip switch settings may cause damage to the unit For this reason the diagram of the factory settings are indicat...

Page 19: ......

Page 20: ......

Page 21: ...erve le droit de modifier tous moments les donn es consid r es n cessaires l amelioration du produit Technical data shown in this booklet are not binding Aermec S p A shall have the right to introduce...