Charge Profile Configuration
The CoolMax SRX allows for extensive flexibility when it comes to charge profile parameters to suit numerous
different modern battery chemistries and manufacturers requirements.
Our programmable charge profile allows for the configuration of the Battery Charge Rate, and the Absorb,
Float, Re-Bulk, and Equalization voltage points.
The default charge profile is suitable for most applications but to determine the optimal charge profile for your
application, please refer to your battery manufacturer’s user manual or datasheet.
The
CoolMax SRX
Default Charge Profiles are as follows:
SRX 600/55-48
SRX 600/70-48
Nominal Battery voltage
48 V
48 V
Max Charge current
55 A
70 A
Absorption voltage
57.6 V
57.6 V
Absorption time
2 Hours
2 Hours
Float Voltage
55.2 V
55.2 V
Re-Bulk Voltage
52 V
52 V
SRX 600/30-120
Nominal Battery voltage
120 V
Max Charge current
30 A
Absorption voltage
144 V
Absorption time
2 Hours
Float Voltage
138 V
Re-Bulk Voltage
126 V
IMPORTANT
An Equalization is only normally required for Flooded Lead-Acid cells that experience
sulfation because of poor charging practices over the lifetime of said cell.
Equalization is
not required,
nor recommended
for LiFePo4 or other lithium-based
battery solutions and will likely cause damage unless otherwise advised by the
battery manufacturer.