51
10 Specifications
The components installed in an indoor air laundry dryer decide on its
dehumidifying performance. Since these components can never be
completely identical the actual performance according to DIN EN 810
may deviate by up to 5% from the specified performance.
General data
Power supply
230 V/50 Hz
Protection class
IP 22
Protection for indoor
swimming pools
RCCB to be installed by user
Operating conditions
+ 3 °C to + 32 °C
40% r. h. to 95% r. h.
Type
Unit
WT 230
WT 240
WT 250
WT 280
Air circulation rate
cbm/h
750
830
870
920
Power consumption watt
max.
569
570
887
1390
Refrigerant R407c
in kg
0.35
0.35
0.55
0.68
GWP: 1.774/ CO2
in t
0.62
0.62
0.975
1.21
Noise level
dB (A)
61
61
60
66
Dimensions
H x W x D
mm
810/639/345
Weight
kg
40
40
42
43
Condensate drain:
Direct condensate drain via hose
Installation
Wall mounting
Warranty period
2 years