background image

page 7 of 14 

 

Ø

  Check whether the bucket is placed in the unit or a drain hose has been 

fastened and laid appropriately.(refer to 5.7) 

Ø

  Set the required humidity value at the hygrostat (refer to 5.5). 

Ø

  If the existing humidity is higher than the set value, the air dryer will start to 

operate. 
If the existing humidity is lower than the set value, the air dryer will not start to  
operate. 

Ø

  The fan starts first and the compressor will start after approx. 3 Minutes. 

 

5.4 Operation panel 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
1 – 

neon green: 

Unit is ready for operating / Voltage is connected 

2 – 

chart with neons: 

Shows the approx. Humidity of the ambient air (in % r.h.) 

3 – 

neon green:

 Dryer is in defrost mode (fan is still working / compressor does   

      not work) 
4 – 

neon red:

 tank is full 

5 - 

Hygrostat

 with knob and chart (refer to 5.5) 

 

5.5 Hygrostat control 

 

The air dryers of the DH-series dispose of a hygrostat for setting the required 
humidity value. This hygrostat is located at the rear side of the unit, in the bucket 
compartment. It makes that the air dryer cuts in as soon as the ambient humidity 
exceeds the preset value. If the humidity value falls below the set value, the 
hygrostat will switch off the complete dryer. 
The hygrostat is placed in the operation panel 
 
 
 
 
 
 
 


 

Summary of Contents for DH 18

Page 1: ...page 1 of 14 Instruction manual _____________________________________ Dehumidifier DH 18 _____________________________________ Valid 01 2011...

Page 2: ...5 6 5 2 Electrical connection 6 5 3 Putting into operation 6 7 5 4 Operation panel 7 5 5 Hygrostat control 7 8 5 6 Air flow 8 5 7 Condensate outlet 9 5 8 Automatic defrosting 10 6 Operating condition...

Page 3: ...ble to send the device safe for guarantee repair In order to save space you open simply the adhesive tape with a knife and you fold the carton 2 Mode of functioning The DH air dryer is built particula...

Page 4: ...rrespondingly and consider this operating manual precisely Using as directed The condensation dryers are intended for the drying of air with atmospheric pressure Risk by accessory Hoses for condensate...

Page 5: ...e air filter must at least conduct 1 meter Before every local alternation of the device switch off the device at the on off switch pull the power plug from the socket and empty the water tank The air...

Page 6: ...technical data of the appliance should be compared to the conditions prevailing in the room of installation 5 3 Putting into operation ATTENTION Before putting the air dryer into operation the instruc...

Page 7: ...perating Voltage is connected 2 chart with neons Shows the approx Humidity of the ambient air in r h 3 neon green Dryer is in defrost mode fan is still working compressor does not work 4 neon red tank...

Page 8: ...eter Please consider Humidity values of a minimum of 40 45 r h can be achieved with a condensation dryer An adsorption dryer is to be employed if lower values are required For this purpose ask your te...

Page 9: ...f the tank and switches on automatically if the empty tank is placed back into the equipment Make sure that the carrying handle is folded correctly back into the tank Optionally a hose 12 mm can be in...

Page 10: ...tive humidity from 40 to 95 r h The use in rooms with higher temperatures 32 C leads to disadvantages at the compressor The use in rooms with lower temperatures 15 C is ineffective and can lead to ici...

Page 11: ...350 Watt 7 2 l 24h at 20 C 60 r h 300 Watt 8 Service Maintenance ATTENTION When performing any repair or maintenance the general safety rules and provisions must be adhered to In order to guarantee a...

Page 12: ...5 4 Pos1 must light up Check the main cable an additional cable the socket and the main fuse The humidity value adjusted at the hygrostat is achieved The unit will start again after exceeding the adj...

Page 13: ...AL air dryers we recommend get in touch with your supplier The producer AERIAL GmbH you reach under 0049 40 526879 0 or www aerial de 10 Disposal Please do not dispose this unit with the domestic wast...

Page 14: ...afety of Machinery EN 50081 1 92 Electromagnetic Compatibility EMC Basic Specification Emitted Interference EN 50082 1 97 Electromagnetic Compatibility EMC Basic Specification Emitted Interference EN...

Reviews: