Aerial Aerocube VT2 Series Instruction Manual Download Page 17

EU DECLARATION OF CONFORMITY 

 

 

 

 

Page 15 of 15 

 

11

 

EU Declaration of Conformity 

EU Declaration of Conformity 
according to EC machinery directive 2006/42/EC, Annex II, 1.A

 

Machinery directive 2006/42/EC  
EMC directive 2014/30/EU  
Low voltage directive 2014/35/EU  

Manufacturer:  

AERIAL GmbH - Systeme zur Luftbehandlung 
Oststraße 148, D-22844 Norderstedt 

Product description:  

Water separator VT2 
 

The product described is a water separator ready for connection.  

Applicable 
standards: 

EN ISO 12100 

Safety of Machinery 

EN 55 014-1:2006 + A1 : 
2009 + A2 : 2011 
EN 61 000-3-2:2014  
EN 61 000-3-3:2013 

Electromagnetic Compatibility (EMC) 

 

This declaration of conformity shall become void if any modification not agreed 
with the manufacturer is made to the device.  

Norderstedt on 15.06.2015  

 

 

 

 

 

 

General Manager

 

 

AERIAL GmbH 

Oststraße 148 

D-22844 Norderstedt

 

 

Summary of Contents for Aerocube VT2 Series

Page 1: ...MADE IN GERMANY DE INSTRUCTION MANUAL Water Separator Series VT2...

Page 2: ...All rights reserved The instruction manual is based on the technical and product specific parameters The manufacturer reserves the right to add supplementary information to the instruction manual Usi...

Page 3: ...ating conditions_______________________________________________________ 7 Installation_________________________________________________________________ 7 5 Operation and operator control _____________...

Page 4: ...u will find information intended to warn you of possible hazards at the beginning of a specific action DANGER Type and source of hazard This symbol in connection with the signal word DANGER refers to...

Page 5: ...designated use Misuse is concerned if the water separator VT2 is used for purposes not included in designated use In these cases the manufacturer does not assume any liability for personal and materi...

Page 6: ...nderstood the instruction manual Safety instructions The devices must not be used under the following conditions in rooms with potentially explosive atmospheres in rooms with aggressive atmospheres e...

Page 7: ...d insulation layer drying in the vacuum mode with compressor or soundbox VP2 VP3 VP6 The connected compressor soundbox VP2 VP3 VP6 draws the air water taken in e g from the insulation layer through th...

Page 8: ...ew cap 3 Screw cap 2 Connection pipe 38 mm 50 mm or 50 pipe Three intake pipes are arranged on the device rear side The intake holes not used can be closed by screw caps Screw caps are included in the...

Page 9: ...r drying in the vacuum mode It works without problems in the temperature range from 0 C to 35 C Installation The devices can be stacked and are provided with fixing points for a belt system on the rig...

Page 10: ...k Read the instruction manual before commissioning the water separator VT2 Operating elements Fig 5 Water separator VT2 control panel 1 On Off switch 5 Appliance socket fuse 16 A 2 Membrane key P 6 Me...

Page 11: ...n connected to the threaded connector for waste water 3 Ensure that the air tube has been connected to the connector for the compressor s page 5 Fig 1 item 2 and to the air intake pipe on the compress...

Page 12: ...nance work WARNING Danger of injury by electric shock and risk of material damage Always observe the general safety instructions when performing any maintenance and service work CAUTION Damage to the...

Page 13: ...1 Tilt and move the housing to and fro so that the residual water can flow out Clean coarse filter Fig 7 Filter box with filter grille Fig 8 Filter grille removed 1 3 Knurled nuts 1 Intake openings 2...

Page 14: ...Problem Possible cause Remedy Compressor soundbox VP2 VP3 VP6 does not start running or has automatically switched off Power plug not plugged into VT2 socket outlet Plug in power plug Socket outlet f...

Page 15: ...proceed as follows 1 Switch off the water separator VT2 via the On Off switch s page 5 Fig 1 item 6 2 Pull the power plug 3 Drain the residual water s fig 6 Storage Store the sound water separator VT...

Page 16: ...rating conditions 0 C to 35 C Type Unit VT2 Pump delivery volume m3 h 9 Pump delivery height m 7 Power consumption of pump watt 380 Dimensions H x W x D mm 507 390 490 Weight kg 18 Power cable length...

Page 17: ...tstra e 148 D 22844 Norderstedt Product description Water separator VT2 The product described is a water separator ready for connection Applicable standards EN ISO 12100 Safety of Machinery EN 55 014...

Page 18: ......

Page 19: ......

Page 20: ...AERIAL GmbH Systeme zur Luftbehandlung Oststrasse 148 D 22844 Norderstedt Phone 0049 0 40 526 879 0 Telefax 526 879 20 E Mail info aerial de Internet www aerial de Dealer stamp...