OPERATION AND OPERATOR CONTROL
Page 10 of 18
Membrane key "Info"
Display also when power plug has been pulled, time 5 seconds.
Press briefly
Operating hours
Temperature in the box
press for 3 s
Software version
Software serial number
Membrane key "Reset"
Press briefly
Reset fault
red LED flashing
Press briefly
Reset after overload
Counter-pressure display
Compressor in normal mode
Compressor at power limit
Compressor overloaded
After 10 seconds of overload:
LED flashes
and
flashes
Compressor off, plug
socket off, fan remains
on
When red LED flashes
press "Reset",
fan on,
compressor on
Commissioning and operator control
1.
Connect the soundbox VP2 / VP3 electrically, s. page 6.
2.
Ensure that air tubes have been connected properly.
Overload
◼◼◼◼◼◼◼◼◼◼◼
V 6.0
SN 12345
123456 h
T1 = 35 C