background image

 

 

 

 

Page 1 of 18 

 

Instruction manual 

Soundbox 

Series  VP2 

 

 

VP3 

 

 

 

        

 

 

 

Summary of Contents for AERCUBE VP2 Series

Page 1: ...Page 1 of 18 Instruction manual Soundbox Series VP2 VP3...

Page 2: ...permit All rights reserved The instruction manual is based on the technical and product specific parameters The manufacturer reserves the right to add supplementary information to the instruction manu...

Page 3: ...___________ 7 Scope of delivery ____________________________________________________________ 7 Operating conditions ________________________________________________________ 7 Installation ____________...

Page 4: ...and dispose of the device from AERIAL properly and safely Therefore keep this instruction manual in a safe place Target groups This instruction manual addresses the users and operators of the devices...

Page 5: ...teps to avert danger which must always be performed WARNING Type and source of hazard This symbol in connection with the signal word WARNING refers to a dangerous situation Failure to observe this war...

Page 6: ...dered contrary to its designated use Misuse is concerned if the soundbox VP2 VP3 is used for purposes not included in designated use In these cases the manufacturer does not assume any liability for p...

Page 7: ...manual accessible to the operator make sure that the operator has read and understood the instruction manual Safety instructions The devices must not be used under the following conditions in rooms wi...

Page 8: ...el with full text display 4 Tube connector intake side The sound box VP2 VP3 is equipped with a side channel compressor installed with vibration damping The installed compressor is air cooled and work...

Page 9: ...n Scope of delivery Soundbox VP2 VP 3 One instruction manual Operating conditions The soundbox VP2 VP3 is intended for use in screed and insulation layer drying and hollow space drying It works withou...

Page 10: ...compared with the conditions prevailing in the room of installation The following items must be checked prior to electrical connection of the soundbox Is the mains voltage in conformity with the volta...

Page 11: ...ng the soundbox VP2 VP3 Operating elements Fig 3 Operating panel Soundbox VP2 VP3 1 Appliance socket 6 Appliance socket fuse 2 On Off switch 7 Membrane key Reset with red LED 3 Display LED matrix blue...

Page 12: ...ED flashing Press briefly Reset after overload Counter pressure display Compressor in normal mode Compressor at power limit Compressor overloaded After 10 seconds of overload LED flashes and flashes C...

Page 13: ...eneral safety instructions when performing any maintenance and service work CAUTION Damage to the device Cleaning agents can cause damage to surfaces Use only mild detergents The cleaning intervals de...

Page 14: ...ert new or cleaned filter Use only original filters to guarantee proper functioning of the soundbox VP2 VP3 Visual inspection Coarse filter see fig 5 arrow in intake socket If the coarse filter is soi...

Page 15: ...e device shall only be carried out by the manufacturer or persons commissioned by him Any work carried out by unauthorised persons shall lead to the forfeiture of all warranty claims Fault messages Di...

Page 16: ...some time To do so proceed as follows 1 Switch off the soundbox via the On Off switch page 6 Fig 1 item 1 2 Pull the power plug Storage Store the soundbox VP2 VP3 in conformity with the specified saf...

Page 17: ...stalled by user Operating conditions 0 C to 35 C Type Unit VP2 VP3 Air circulation rate m h 140 150 Max differential pressure Vacuum Pressure mbar mbar 140 160 170 190 Power consumption watt max 800 1...

Page 18: ...e at atmospheric pressure Operating the device within the limits of designated use also involves observing the specified operating conditions Any use of the device going beyond the designated use spec...

Page 19: ...0 2010 11 Safety of machinery General principles for design Risk assessment and risk reduction ISO 12100 2010 EN 60204 1 2006 A1 2009 Safety of machinery Electrical equipment of machines Part 1 Genera...

Page 20: ...Page 18 of 18 Dealer stamp Dantherm GmbH Systeme zur Luftbehandlung Oststra e 148 D 22844 Norderstedt Phone 0049 0 40 526 879 0 Telefax 526 879 20 E Mail info de dantherm com Internet www aerial de...