background image

Page 3 of 15 

1.General advice 

 

You have bought an air dryer made by AERIAL thus deciding for a proven quality 
product "Made in Germany". If f there are any questions, you will find some advice 
in this manual how to eliminate such difficulties as quickly as possible. 
 

ATTENTION:

 

Immediately after receipt, you should check your air dryer for transport damage! In 
the case of damage, you should inform the forwarding agent, parcel service, post 
office etc. accordingly upon receipt, and make a note of it on the forwarding 
documents! 

 

If a transport damage should be noticed after unpacking the equipment, please 
contact immediately your respective seller or specialized dealer.  
 
Before putting your air dryer into operation for the very first time, these instructions 
for operation should be studied very thoroughly. Thus, you can make sure that this 
appliance will operate perfectly for a long period of time saving yourselves 
unnecessary repairs and expenses. 
 
In the case of malfunction disconnect your appliance and ensure that it is not 
connected again by taking the mains plug out of the socket. 
 
Please, keep the device wrapping in order to be able to send the device safe for 
guarantee repair. In order to save space you open simply the adhesive tape with a 
knife and you fold the carton. 
 
 

2.Mode of functioning 

 

The AD-air dryer is constructed exclusively for air drying in closed rooms. That 
dehumidifier can prevent the formation of condensation, eliminate too high air 
humidity and hold a specific air humidity constant. The time which the dryer requires 
in order to achieve a specific humidity depends essentially on the environmental 
conditions. The attainable humidity value is equally dependent on the environmental 
conditions. 
The AD-dehumidifier works according to the condensation principle with heat 
recovery. The fan (shown indicatively below) suck the moist air through a cool 
register (evaporator). The air becomes so far chilled under the point of 
condensation here, that the moist air condense as water and flows into the water-
collecting tank. The chilled and dried air is warmed up at the condenser again. 
Through the heat pump effect, the outlet air is some degrees warmer than the 
sucked room air. Useful energy can conducted up to 3-fold of the electrical power 
consumption. The absolute moisture of air is lowered continuously by the 
continuous circulation of the room air through the device. The surplus moisture is 
removed safely and efficiently. 
 
 
 

Summary of Contents for AD 740

Page 1: ...Page 1 of 15 Instruction manual _____________________________________ Dehumidifier AD 740 750 770 790 _____________________________________ valid 02 2008...

Page 2: ...50 6 5 4 Operation panel AD 770 790 7 5 5 Description of operation panel 7 5 6 Hygrostat control 7 8 5 7 Condensate outlet AD 740 750 9 5 8 Condensate outlet AD 770 790 9 5 9 Condensate pump option 9...

Page 3: ...er to be able to send the device safe for guarantee repair In order to save space you open simply the adhesive tape with a knife and you fold the carton 2 Mode of functioning The AD air dryer is const...

Page 4: ...tion dryers are intended for the drying of air with atmospheric pressure Risk by accessory Hoses for condensate removal and air filters must be fit expertly and must not take the protective devices of...

Page 5: ...therwise it must be secured against rolling off That dehumidifier can be transported upright or laid flat The upright transportation is to be preferred if possible The appliance must be used exclusive...

Page 6: ...eturn into the compressor We recommend this procedure since it extends the service life of the compressor Put the plug into the socket Check whether the bucket is placed in the unit AD 730 740 standar...

Page 7: ...andard The unit has switched off because the humidity in thet room is ok has achieved the requested value 6 Hygrostat see 5 6 Hygrostat control 7 On Off Switch 8 Make sure a free space in front of air...

Page 8: ...umidity values of a minimum of 40 45 r h can be achieved with a condensation dryer An adsorption dryer is to be employed if lower values are required For this purpose ask your technical consultant Opt...

Page 9: ...ater tank at AD 770 790 optional extra does NOT disconnect the device in the case of full state During unattended using AD 770 790 with built in pump is advisable 5 9 Condensate pump optional Optional...

Page 10: ...ooms of aggressive atmospheres for example ammonia and wood acid In rooms with water which shows a pH value outside of 7 0 to 7 4 Remark In The case of lower pH value corrosion occurs at all metals an...

Page 11: ...NTION When performing any repair or maintenance the general safety rules and provisions must be adhered to In order to guarantee a troublefree function of the dryer the device should be cleaned regula...

Page 12: ...s out of operation Fan and compressor does not run Is the dryer switched on The On Off switch must be in position I and must light up Is the unit supplied with voltage The On Off switch must light up...

Page 13: ...se the dryer needs some time to remove that water and to achieve an acceptable humidity in that room ATTENTION The appliance must be repaired by trained and expert personnel only In the case of interv...

Page 14: ...Page 14 of 15 11 Circuit diagram...

Page 15: ...EN ISO 12100 Safety of Machinery EN 50081 1 92 Electromagnetic Compatibility EMC Basic Specification Emitted Interference EN 50082 1 97 Electromagnetic Compatibility EMC Basic Specification Emitted I...