19
Procedure
1. Make sure that the discharge hose
runs into a drain or suitable container.
2. Switch on the pump at the pump con-
trol section. To do this, press and hold
the toggle switch until the condensate
water has been pumped away.
Switching off
Procedure
1. Empty the basin or pump water out of
AD 810 if necessary.
2. Press the
key.
10 Maintenance and care
WARNING! Damage to health from
dust!
Only clean the dehumidifier and filter
with compressed air in open spaces.
Wear a protective mask and goggles.
Important! Damage to property!
Cleaning agents can damage surfaces.
Only use mild detergents.
Only use approved original spare
parts.
Cleaning and inspection
Procedure
1. Switch off the dehumidifier.
2. Unplug the mains plug.
3. Remove and clean the air filter (e.g.
with vacuum cleaner) or replace it.
4. Check the discharge nozzle and dis-
charge hose, if connected.
5. Insert a new or clean filter. Only use an
original filter.
6. Plug in the mains cable.
7. Switch on the dehumidifier if neces-
sary.
Spare parts and customer service
If you have any questions about the de-
humidifier or require spare parts, contact
your authorised dealer or AERIAL Service.