34 / 36
TF6746_A_NOT_DXA230_REFERENCE
Aereco S.A.
DXA 230
Standard code
DXA1705
DXA1706
Ecodesign
Label (EU Ecodesign Directive)
A
Airflow characteristics
Max. airflow
m
3
/h
230
Other nominal airflows
m
3
/h
(40) 80 / 140 / 200 / 230 (250)
Airflow compensation (filter clogging)
automatic
Airflow balance (supply and exhaust)
automatic
Acoustics
Sound power level Lw @ 161 m
3
/h, 50 Pa
dB(A)
52
Certifications
CE
Electrics
Power supply
230 VAC, 50 Hz
Motor type
EC (x2)
Power consumption @ 161 m
3
/h @50 Pa
W
36,5
Power consumption @ 230 m
3
/h @50 Pa
W
92,0
Demand control
Compatible versions of DX System
REFERENCE
Characteristics
Exchanger
polystyrene / counter flow type / 93% efficiency
Filters
on supply air: 2 x F7 / on exhaust air: 1 x G4
Weight
kg
23
Colour
Black
Material (main)
expanded polypropylene (EPP)
Dimensions
mm
with duct connectors: 1428 x 552 x 545 without duct connectors: 1188 x 552 x 545
Installation
Max. number of main rooms
6
Max. number of technical rooms
5
Connections
2 x (2 x ø160 mm)
Installation
vertical only, to the wall / 2 x 4 points of attachment
Other functions
Interface
Web pages
Bypass
controlled by outdoor temperature / also used for free-cooling
Preheating (optional)
with resistance in fresh air ductwork from outside
Condensation management
condensate pump
exhaust through siphon
Temperature of use
Installation room
frost free: +5°C < T°< +50°C
Incoming outdoor fresh air or Extract