21
a)
Mark
-
AERAULIQA
b)
Model
-
QR280ABP
c)
SEC class
-
A
A
B
c1)
SEC warm climates
kWh/m2.a
-15,2
-11
-7,2
c2)
SEC average climates
kWh/m2.a
-39,3
-34,4
-30,1
c3)
SEC cold climates
kWh/m2.a
-76,8
-70,7
-65,5
Energy label
-
Yes
d)
Unit typology
-
Residential - bidirectional
e)
Type of drive
-
variable speed drive
f)
Type of Heat Recovery System
-
heat recovery
g)
Thermal efficiency of heat recovery
%
80
h)
Maximum flow rate @100Pa
m3/h
256
i)
Electric power input at maximum flow rate
W
160
j)
Sound power level (L
WA
)
dBA
56
k)
Reference flow rate
m3/h
179
l)
Reference pressure difference
Pa
50
m)
Specific power input (SPI)
W/m3/h
0,385
n1)
Control factor
-
0,65
0,85
1
n2)
Control typology
-
Local demand
control
Central demand
control
Manual control
(no DCV)
o1)
Maximum internal leakage rate
%
1,5
o2)
Maximum external leakage rate
%
1,5
p1)
Internal mixing rate
%
N/A
p2)
External mixing rate
%
N/A
q)
Visual filter warning
-
Visual filter warning on display
r)
Instructions to install regulated grilles
-
N/A
s)
Internet address for pre/disassembly instructions
-
www.aerauliqa.com
t)
Airflow sensitivity to pressure variations
%
N/A
u)
Indoor/outdoor air tightness
m3/h
N/A
v1)
AEC - Annual electricity consumption - warm climates
kWh
2
3,5
4,8
v2)
AEC - Annual electricity consumption - average
climates
kWh
2,5
3,9
5,3
v3)
AEC - Annual electricity consumption - cold climates
kWh
7,9
9,3
10,7
w1)
AHS - Annual heating saved - warm climates
kWh
20,3
19,7
19,3
w2)
AHS - Annual heating saved - average climates
kWh
44,9
43,6
42,6
w3)
AHS - Annual heating saved - cold climates
kWh
87,8
85,3
83,4
ErP Directive - regulations 1253/2014 - 1254/2014