15

q) 

Segnale avvertimento filtro - Visual filter warning

 

Alarme visuelle des filtres - optischen Filterwarnanzeige - 
Señal visual de aviso del filtro

-

Assente; absent; absent; abwesend; ausente

r) 

Istruzioni installazione griglie - Instructions to install regulated 
grilles - Instructions de l’installation de grilles réglementées - 
Anweisungen zur Anbringung regelbarer Gitter - Instrucciones 

para la instalación de rejillas reguladas

-

N/A

s) 

Indirizzo Internet istruzioni di preassemblaggio/ 
disassemblaggio

 

Internet address for preassembly/disassembly instructions

 

Adresse internet concernant les instructions de 
préassemblage/démontage

 

Internetanschrift für Anweisungen zur Vormontage/Zerlegung

 

Dirección de internet para las instrucciones de montaje y 

desmontaje

-

www.aerauliqa.com

t) 

Sensibilità del flusso alle variazioni di pressione

 

Airflow sensitivity to pressure variations 

 

Sensibilité du flux d’air aux variations de pression

 

Druckschwankungsempfindlichkeit des Luftstroms

 

Sensibilidad del flujo de aire a las variaciones de presión

%

5%

u) 

Tenuta all’aria interna/esterna - Indoor/outdoor air tightness

 

Ètanchéité à l’air intérieur/extérieur - Luftdichtheit zwischen 
innen und auβen - Estanqueidad al aire interior/exterior

m3/h

20

v1)

Consumo annuo di energia (AEC) climi caldi

 

AEC - Annual electricity consumption - warm climates

 

Consommation d’électricité annuelle (CEA) en climat chaud

 

jährlicher Stromverbrauch (JSV) für warmen Klimatyp

 

Consumo de electricidad anual (CEA) en clima cálido

kWh

3

v2)

Consumo annuo di energia (AEC) climi temperati

 

AEC - Annual electricity consumption - average climates

 

Consommation d’électricité annuelle (CEA) en climat moyen

 

jährlicher Stromverbrauch (JSV) für durchschnittlichen 

Klimatyp 

Consumo de electricidad anual (CEA) en clima templado 

kWh

3,4

v3)

Consumo annuo di energia (AEC) climi freddi

 

AEC - Annual electricity consumption - cold climates

 

Consommation d’électricité annuelle (CEA) en climat froid

 

jährlicher Stromverbrauch (JSV) für kalten Klimatyp

 

Consumo de electricidad anual (CEA) en clima frío

kWh

8,8

w1)

Risparmio di riscaldamento annuo (AHS) climi caldi

 

AHS - Annual heating saved - warm climates

 

Èconomie annuelle de chauffage (EAC) en climat chaud

 

jährlicher Einsparung an Heizenergie (JEH) für warmen 

Klimatyp 

Ahorro anual en calefacción (AAC) en clima cálido

kWh

20,8

w2)

Risparmio di riscaldamento annuo (AHS) climi temperati

 

AHS - Annual heating saved - average climates

 

Èconomie annuelle de chauffage (EAC) en climat moyen

 

jährlicher Einsparung an Heizenergie (JEH) für 
durchschnittlichen Klimatyp

 

Ahorro anual en calefacción (AAC) en clima templado

kWh

46

w3)

Risparmio di riscaldamento annuo (AHS) climi freddi

 

AHS - Annual heating saved - cold climates

 

Èconomie annuelle de chauffage (EAC) en climat froid

 

jährlicher Einsparung an Heizenergie (JEH) für kalten Klimatyp

 

Ahorro anual en calefacción (AAC) en clima frío 

kWh

90,1

Summary of Contents for QR100M

Page 1: ...e required 3 3 5 Rating Label 4 4 Transport and Storage 4 5 Installation 4 5 1 Unpacking 4 5 2 Where how to install 4 5 3 Installation 5 5 4 Electric Connections 6 6 Commissioning 8 6 1 Setting Fan speed 8 6 2 Before Starting the System 9 7 Operation 9 7 1 Single speed operation 9 7 2 Two speed operation 9 7 3 Variable speed operation with CTRL M remote manual controller accessory on request 9 7 4...

Page 2: ...device should not be used for applications other than those specified in this manual The device is not intended for use by persons including children with reduced physical sensory or mental capacities or those with a lack of experience and knowledge unless they have been given supervision or instruction concerning use of the device from a person responsible for their safety Children should be supe...

Page 3: ...inage Summer condensation drainage Fig 3 a Weight Kg 12 5 F E E F 3 2 Dimensions mm and Weight 3 3 Connections 3 4 Space required Make sure that enough space is left around the unit to allow easy maintenance removal of the front cover for access to filters and terminal box It is recommended to leave at least 1m distance between the side grilles supply and extract and the perpendicular walls ...

Page 4: ...le from outside The unit must always be mounted horizontally Mount the unit on flat surface wall It s important that the unit is completely leveled before it is put into operation Place the unit preferably in the middle of the area to be ventilated When choosing the location it should be kept in mind that the unit requires maintenance regularly and that the inspection door should be easily accessi...

Page 5: ...acket on the wall make sure that the bracket is properly installed to support the unit weight 5 e Fix the spigots in the wall safely 5 f Hook the main body of the unit at the bracket making sure that the two holes on the rear side of the casing are in line with the spigots fixed at the wall 5 g Fix the main body to the wall by means of screws not supplied 5 h Make sure that the unit is completely ...

Page 6: ...es below show the wiring diagrams 5 k Single speed operation 1 2 3 4 S 1 S 2 S 3 G N D N L V1 V2 CTrL S GND POT 10 S1 S2 S3 II I L L L 1 1 1 5 l Two speed operation S 1 S 2 S 3 G N D 1 2 3 4 GND POT 10 N L V1 V2 CTrL m N L 5 m Variable speed operation with CTRL M remote manual controller S 1 S 2 S 3 G N D 1 2 3 4 GND POT 10 N L V1 V2 1 10V BALLAST 5 n Variable speed operation through external domo...

Page 7: ...equest 5 q 1 2 3 4 Operation 0 0 0 0 Single speed 1 0 0 0 Two speed 0 1 0 0 Variable speed with CTRL M remote manual controller 0 1 1 0 Variable speed throught external domotic BMS system or ballast potentiometer 1 0 0 0 Three speed with SEL 3V 1 1 0 0 Three speed with CTRL S Dip switch 1 2 3 4 1 0 I II ...

Page 8: ...f the heat exchanger The heat exchanger is tested at the University of Luzern Hochschule Lezern EXTERNAL INTERNAL Curve Speed W max m3 h max A min 24 8 19 B 30 9 24 C 43 13 40 D 61 22 57 E 75 34 71 F 93 51 88 G max 100 58 100 Working point W m3 h SPI W m3 h ɳt 1 I 8 3 21 0 395 93 II 13 37 0 351 91 III 21 8 54 0 404 89 IV 33 1 66 0 5015 87 V 50 2 82 0 6122 85 VI 57 5 93 0 6183 84 1 Termal efficienc...

Page 9: ...t Filters are mounted correctly The unit is installed in accordance with the instructions The unit is correctly wired Outdoor air intake is positioned with sufficient distance to pollution sources kitchen ventilator exhaust central vacuum system exhaust or similar The unit is correctly set and commissioned 7 5 Three speed operation with SEL 3V speed selector accessory on request The unit runs at t...

Page 10: ...ween 10 100 The motor bearings are life time lubricated and maintenance free Filters The filters are of filter quality G4 for both the supply air and extract air filter The filters need to be cleaned regularly and replaced when polluted during maintenance New sets of filters can be acquired from your installer or wholesaler Heat exchanger The unit is equipped with a highly efficient counter flow p...

Page 11: ...y three months with a vacuum cleaner and replace the filters every year This may differ per situation depending on internal and external environmental conditions fig 8 b c d e f WARNING Make sure that the mains supply to the unit is disconnected before performing any installation service maintenance or electrical work ...

Page 12: ...r with a vacuum cleaner This may differ per situation depending on internal and external environmental conditions and on frequency of filter cleaning Do not move the balance clips fig 8 g h l m n o p Check the condensation drainage remove the front covers and if necessary clean the condensation tray Check the U bend efficiency 8 4 Service WARNING Make sure that the mains supply to the unit is disc...

Page 13: ...impellers Cleaning required 2 Check that the fans are firmly in place within the unit 3 Check that the unit is firmly fixed to the mounting bracket Excessive air noise 1 Check setting of fan speed in the terminal box or on the remote controls 2 Check grilles Re setting or cleaning of grilles required Gurgling noise 1 Drainage connections have not been installed correctly 2 Drainage connections bel...

Page 14: ...rbée au débit maximal elektrische Eingangsleistung bei höchstem Luftvolumenstrom Potencia eléctrica de entrada con el caudal máximo W 58 j Livello potenza sonora LWA Sound power level LWA Niveau de puissance acoustique LWA Schallleistungspegel LWA Nivel de potencia acústica LWA dBA 56 k Portata di riferimento Reference flow rate Débit de rèfèrence Bezugs Luftvolumenstrom Caudal de referencia m3 h ...

Page 15: ...mates Consommation d électricité annuelle CEA en climat chaud jährlicher Stromverbrauch JSV für warmen Klimatyp Consumo de electricidad anual CEA en clima cálido kWh 3 v2 Consumo annuo di energia AEC climi temperati AEC Annual electricity consumption average climates Consommation d électricité annuelle CEA en climat moyen jährlicher Stromverbrauch JSV für durchschnittlichen Klimatyp Consumo de ele...

Page 16: ...ia Corsica 10 25125 Brescia C F e P IVA VAT 03369930981 REA BS 528635 Tel 39 030 674681 Fax 39 030 6872149 www aerauliqa it info aerauliqa it Aerauliqa srl si riserva il diritto di modificare apportare migliorie ai prodotti e o alle istruzioni di questo manuale in qualsiasi momento e senza preavviso CFI00041 04 0616 ...