5
Make sure filters are in correct order
- pre-filter / carbon filter / HEPA
filter - and inserted into filter frame
(Fig 16).
IMPORTANT: Make sure filter
detection area aligns with window
in filter frame (Fig 17).
Close front panel by pressing
firmly until both sides latch closed
(Fig 19).
The power connector (B, in Fig
12) will carry power from the rear
housing to the main housing once
the assemblies are fully seated. The
main assembly will attach to the rear
housing assembly by the four screws
previously removed (Fig 5 & 6). Two
snap hooks (A, in Fig 12) will hold the
main and rear assemblies together
until the screws can be installed.
Carefully align the main assembly
with the rear housing assembly.
Slowly press into place until snap is
heard, and there is no gap between
the assemblies (Fig 13). The unit
should now support its own weight.
Open front panel by pressing
latches on both sides of unit. Allow
door to open fully. Insert filters
– IMPORTANT: make sure filter
detection window is aligned in
upper right corner (Fig 18).
To restrict access to the control panel
and filters the unit can be locked. To
lock, insert the key provided and
rotate clockwise ¼ turn (Fig 21).
Once the unit is closed re-establish
power. Lights on the control panel will
be visible through the lens, indicating
the unit is operational (Fig 20). The
power light indicator will flash once
a second.
Install six screws (previously removed) to secure main assembly to rear
housing assembly (Fig 14 & 15).
RE-INSTALLING FILTERS
LOCKING ACCESS PANEL
MAIN ASSEMBLY INSTALLATION
WARNING:
To avoid the risk of electrocution confirm the electrical supply has been disconnected or switched off before continuing any installation work.
IMPORTANT:
Make sure all plastic wrap is removed from filters.
Fig 16
Fig 17
Fig 18
Fig 19
Fig 20
Fig 21
Fig 14
Fig 12
Fig 13
Fig 15
1
2
3
4
5
6
1
2
3
4
5
6
A
A
B