AEQ
NETBOX 4 MH
Audio over IP multichannel interface
16
The NETBOX4MH "Device Name", that we can change later, is displayed in "Netbox4MH"
section. Its associated "Password" can also be modified. The changes will be applied when
pressing "Change" associated button. When a password is established, only the users that
know this password will be able to control the unit by means of "NetBox4MH" RTC application.
"GPIOs" section allows you to activate/deactivate the "Transport" mode in
order to manage or not the STUDIOBOX control box from the general purpose
GPIOs. Once this section is configured, the changes will be applied by
pressing "Change" associated button. See section 2.3 of this manual.
"Device Address" section allows you to configure the IP parameters of the Ethernet interface of
the unit:
-
"IP": valid IP address associated with that interface.
-
"Mask": valid subnet mask associated with that interface.
-
"Gateway": valid gateway or network gateway address associated with that interface.
-
"MAC": valid MAC address associated with that interface (this parameter is
automatically configured depending on the IP address assigned to the unit).
Once those parameters are configured, the changes will be applied by pressing “Change Ip
Address” button. Confirmation is requested (then the unit will reset).
If there is more than one NETBOX 4 MH device reachable in the network, each of them must
be individually connected and its IP changed to a unique value in order to avoid network
conflicts. This is done in the "Device Address" section fields.
This procedure is mandatory and required when several units are to be installed, as all of them
come with the default IP address 172.31.39.1 from factory. At the same time, a name that is
easily recognizable by the users can be assigned, and a password defined, so that
unauthorized people cannot control it from the real time control application, and this way,
inadvertent accesses on the wrong devices in networks with several devices (for example, when
several studios are installed) are prevented.
IMPORTANT NOTICE: In cases where the control IP address of the device that we want to
connect to is unknown, a procedure that allows for the return to the default configuration has
been defined (included in the "Extras" menu of the CD furnished with the unit). If you have any
doubt, please consult AEQ Technical Service (
).
The “Factory” button allows you to return to initial Factory parameters.
The “Reset” button allows you to restart the unit.
Confirmation is requested for both options.