5
Press and hold
20 seconds and
released
Reset Garage Door Controller to Factory Default:
1. Make sure the Garage Door Controller is connected to the power
supply.
2. If holding time more than one second, the Network LED will fast
blink. If holding time more than 20seconds, Network LED will be on
for 2 seconds, which indicates the reset operation is successful,
otherwise please repeat from step1 to step2.
Note
:
1. This procedure should only be used when the primary controller is
inoperable.
2. Reset Garage Door Controller to factory default settings will:
a), remove Garage Door Controller from Z-Wave network state;
b), delete the Association setting;
c), restore the configuration settings to the default.
Switch
Button
Click one time
Toggle the door to Open/close/stop.
/-
Click one time
Switch the alarm sound to the next sound.
Press and hold
Increase or decrease the volume.
5. Special Rule of Each Command
5.1 Z-Wave Plus Info Report Command Class
Parameter
Value
Z-Wave Plus Version
1
Role Type
5 (ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SL AVE_ALWAYS_ON)
Node Type
0 (ZWAVEPLUS_INFO_REPORT_NODE_TYPE_ZWAVEPLUS_NODE)
Installer Icon Type
0x1E00 (ICON_TYPE_GENERIC_BARRIER_OPERATOR)
User Icon Type
0x1E00 (ICON_TYPE_GENERIC_BARRIER_OPERATOR)
6. Special Rule of Each Command
6.1 Association CC
The Garage Door Controller supports 2 association groups and Max 5 nodes for each group..
Association
Group
Nodes Send
Mode
Send commands
Group 1
0
N/A
N/A
1
Single
Cast
When the state of load(position status) is changed:
1, Set Configuration parameter 80 to 0
:
Reserved
(
Default
)
.
2, Set Configuration parameter 80 to 1
:
Send Hail CC.
3, Set Configuration parameter 80 to 2: Send the position info.
[2,5]
Group 2
0
N/A
N/A