Size: 1 Byte, Default Value: 50
Setting
Description
0 - 100
Brightness level range is 0 to 100%.
Parameter 90: Enable/Disable the function of parameter 91 and 92.
This parameter is used to Enable/Disable the function of parameter 91 and 92.
Size: 1 Byte, Default Value: 1
Setting
Description
0
Configuration Parameters 91 and 92 are Disabled
1
Configuration Parameters 91 and 92 are Enabled
Parameter 91: Induce an automatic report
This parameter is used to induce an automatic report when the change of the current power is more/less than the threshold in wattage.
Size: 2 Byte, Default Value: 25
Setting
Description
0 - 32767
The threshold can be set from 0 to 32767 watt.
Parameter 92: Induce an automatic report
This parameter is used to induce an automatic report when the change of the current power is more/less than the threshold in percentage.
Size: 1 Byte, Default Value: 5
Setting
Description
0 - 100
The threshold can be set from 0 to 100 percent.
Parameter 100: Reset Parameter 101 - 103
Size: 1 Byte, Default Value: 0
Setting
Description
1
Reset Parameter 101-103
Parameter 101: To set which report need to be sent.
This parameter is used to configure which reports need to be sent in Report Group 1.The values corresponding to the first four bits of the parameter value
may be combined to create different combinations of reports that you wish to have sent. For example, instantaneous Current is the value 2 and
instantaneous Watts is the value 4, so setting parameter 101 to a value of 6 will result in both instantaneous Current and instantaneous Watts to be
reported. See the full description of the parameter values for other possible settings.
Size: 4 Byte, Default Value: 4
Setting
Description
1
Report Instantaneous Voltage
2
Report Instantaneous Current (Amperes)
4
Report Instantaneous Watts
8
Report Accumulated kWh
Parameter 102: To set which report need to be sent.
This parameter is used to configure which reports need to be sent in Report Group 2.The values corresponding to the first four bits of the parameter value
may be combined to create different combinations of reports that you wish to have sent. For example, instantaneous Current is the value 2 and
instantaneous Watts is the value 4, so setting parameter 102 to a value of 6 will result in both instantaneous Current and instantaneous Watts to be
reported. See the full description of the parameter values for other possible settings.
Size: 4 Byte, Default Value: 8
Setting
Description
1
Report Instantaneous Voltage
2
Report Instantaneous Current (Amperes)
4
Report Instantaneous Watts
8
Report Accumulated kWh
Parameter 103: To set which report need to be sent.
This parameter is used to configure which reports need to be sent in Report Group 3.The values corresponding to the first four bits of the parameter value
may be combined to create different combinations of reports that you wish to have sent. For example, instantaneous Current is the value 2 and
instantaneous Watts is the value 4, so setting parameter 103 to a value of 6 will result in both instantaneous Current and instantaneous Watts to be
reported. See the full description of the parameter values for other possible settings.