Size: 1 Byte, Default Value: 50

Setting

Description

0 - 100

Brightness level range is 0 to 100%.

Parameter 90: Enable/Disable the function of parameter 91 and 92.
This parameter is used to Enable/Disable the function of parameter 91 and 92. 
Size: 1 Byte, Default Value: 1

Setting

Description

0

Configuration Parameters 91 and 92 are Disabled

1

Configuration Parameters 91 and 92 are Enabled

Parameter 91: Induce an automatic report
This parameter is used to induce an automatic report when the change of the current power is more/less than the threshold in wattage. 
Size: 2 Byte, Default Value: 25

Setting

Description

0 - 32767

The threshold can be set from 0 to 32767 watt.

Parameter 92: Induce an automatic report
This parameter is used to induce an automatic report when the change of the current power is more/less than the threshold in percentage. 
Size: 1 Byte, Default Value: 5

Setting

Description

0 - 100

The threshold can be set from 0 to 100 percent.

Parameter 100: Reset Parameter 101 - 103

Size: 1 Byte, Default Value: 0

Setting

Description

1

Reset Parameter 101-103

Parameter 101: To set which report need to be sent.
This parameter is used to configure which reports need to be sent in Report Group 1.The values corresponding to the first four bits of the parameter value
may be combined to create different combinations of reports that you wish to have sent. For example, instantaneous Current is the value 2 and
instantaneous Watts is the value 4, so setting parameter 101 to a value of 6 will result in both instantaneous Current and instantaneous Watts to be
reported. See the full description of the parameter values for other possible settings. 
Size: 4 Byte, Default Value: 4

Setting

Description

1

Report Instantaneous Voltage

2

Report Instantaneous Current (Amperes)

4

Report Instantaneous Watts

8

Report Accumulated kWh

Parameter 102: To set which report need to be sent.
This parameter is used to configure which reports need to be sent in Report Group 2.The values corresponding to the first four bits of the parameter value
may be combined to create different combinations of reports that you wish to have sent. For example, instantaneous Current is the value 2 and
instantaneous Watts is the value 4, so setting parameter 102 to a value of 6 will result in both instantaneous Current and instantaneous Watts to be
reported. See the full description of the parameter values for other possible settings. 
Size: 4 Byte, Default Value: 8

Setting

Description

1

Report Instantaneous Voltage

2

Report Instantaneous Current (Amperes)

4

Report Instantaneous Watts

8

Report Accumulated kWh

Parameter 103: To set which report need to be sent.
This parameter is used to configure which reports need to be sent in Report Group 3.The values corresponding to the first four bits of the parameter value
may be combined to create different combinations of reports that you wish to have sent. For example, instantaneous Current is the value 2 and
instantaneous Watts is the value 4, so setting parameter 103 to a value of 6 will result in both instantaneous Current and instantaneous Watts to be
reported. See the full description of the parameter values for other possible settings. 

Summary of Contents for Smart Switch 6

Page 1: ...ating to the unit s operating status Its surface has a Smart RGB LED which can be used for indicating the output load status or strength of the wireless signal You can configure its indication colour according to your favour The Smart Switch 6 is also a security Z wave device and supports Over The Air OTA feature for the products firmware upgrade Prepare for Installation Reset Please read the user...

Page 2: ...air The update function needs to be supported by the central controller Once the controller starts the update process perform the following action to confirm the firmware update In the case that you need to firmware update your Smart Switch 6 please refer to this article here https aeotec freshdesk com solution articles 6000134294 smart switch 6 firmware v1 03 update Association one device control...

Page 3: ...ue 65536 16777215 Range of green color value 16777215 2147483647 Range of blue color value Parameter 80 Enable Disable to send notifications to associated devices to associated devices This parameter is used to Enable Disable to send notifications to associated devices in Group 1 when the state of Smart Switch Gen5 load is changed Size 1 Byte Default Value 0 Setting Description 0 Send Nothing Disa...

Page 4: ... 6 will result in both instantaneous Current and instantaneous Watts to be reported See the full description of the parameter values for other possible settings Size 4 Byte Default Value 4 Setting Description 1 Report Instantaneous Voltage 2 Report Instantaneous Current Amperes 4 Report Instantaneous Watts 8 Report Accumulated kWh Parameter 102 To set which report need to be sent This parameter is...

Page 5: ...ending report in Report Group 3 Size 4 Byte Default Value 600 Setting Description 0 268435456 Interval Seconds Parameter 200 Partner ID This parameter is used to configure the partner ID Size 1 Byte Default Value 0 Setting Description 0 Aeon Labs Standard Product 1 255 Partner ID of Partner Product Parameter 252 Enable Disable Lock Configuration This parameter is used to enable disable Lock all co...

Page 6: ...Classes Basic Hail Switch Binary Explanation of Z Wave specific terms Controller is a Z Wave device with capabilities to manage the network Controllers are typically Gateways Remote Controls or battery operated wall controllers Slave is a Z Wave device without capabilities to manage the network Slaves can be sensors actuators and even remote controls Primary Controller is the central organizer of ...

Page 7: ...es and functions c 2019 Z Wave Europe GmbH Antonstr 3 09337 Hohenstein Ernstthal Germany All rights reserved www zwave eu The template is maintained by Z Wave Europe GmbH The product content is maintained by Z Wave Europe GmbH Supportteam support zwave eu Last update of the product data 2017 12 27 14 40 26 ...

Reviews: