If you are using double-sided tape, wipe the two surfaces clean of any oil or dust with a damp towel. When the surface
has completely dried, peel one side of the tape back and attach it to the corresponding section on the rear side of the
mounting plate.
You can choose each of way from these 2 installations above. Just need to note if the environment temperature of the
garage door is less than 0 , we suggest to choose the first way (using screws to affix the mounting plate) that would
be more stable.
4. Lock your Sensor on the mounting plate.
Press and hold the Latch Button, and then push the Sensor into the mounting plate.
After completing all installation steps, you may need to test your Garage Door Controller to see if it has been
successfully installed. You can implement this via short pressing the Switch Button on the Garage Door Controller.
When you press the Switch Button, you will see the alarm LED blink and ring the alarm sound. After about 5 seconds,
the garage door will move to a full open or closed position. If you press the Switch Button again, the garage door will
immediately stop moving. If not, please check or repeat the steps above.
Note: If you have confirmed the installation is successful, you need to calibrate the Sensor once. For detailed
calibration steps, please refer to the “Configuration Parameter 34” in the engineering spec document of Garage
Door Controller.
The following instructions will tell you how to remove your Garage Door Controller from your Z-Wave network via an
Aeotec by Aeon Labs’ Z-Stick or Minimote controller. If you are using another Z-Wave controller as your main controller,
please refer to their respective manual on how remove devices from your network.
If you’re using a Z-Stick:
If your primary controller is missing or inoperable, you may wish to reset your Garage Door Controller to its default
factory settings. To do this, press and hold the Z-Wave Button for 20 seconds and then release it. Your Garage Door
Controller will now be reset to its original settings, and the Network LED will be solid for 2 seconds and then start slow
blinking to confirm a success.
Model Number: ZW062
Power Supply: 5V DC Adapter for Garage Door Controller. CR2 Lithium battery 3V, 800mA for Sensor.
Max Alarm Power: 2W.
Max Standby Power: 1W.
Max Volume: 105dB.
Operating Temperature: -10 to 45 .
Storage Temperature: -20 to 70 .
Supported Audio Formats: MP3 within 320 Kbps or WAV at 1411 Kbps.
Operating Distance: Up to 980 feet/300 metres outdoors.
1. If your Z-Stick is plugged into a gateway or a computer, unplug it.
2. Take your Z-Stick to your Garage Door Controller.
3. Press the Action Button on your Z-Stick.
4. Press the Z-Wave Button on your Garage Door Controller.
5. If your Garage Door Controller has been successfully removed from your network, its Network LED will blink. If the
removal was unsuccessful, the Network LED will not blink.
6. Press the Action Button on the Z-Stick to take it out of removal mode.
If you’re using a Minimote:
1. Take your Minimote to your Garage Door Controller.
2. Press the Remove Button on your Minimote.
3. Press the Z-Wave Button on your Garage Door Controller.
4. If your Garage Door Controller has been successfully removed from your network, its Network LED will blink. If the
removal was unsuccessful, the Network LED will not blink.
5. Press any button on your Minimote to take it out of removal mode.
Removing your Garage Door Controller from a Z-Wave network.
Reset your Garage Door Controller.
Advanced functions.
Technical specifications.
Warranty.
Aeon Labs warrants to the original purchaser of Products that for the Warranty Period (as defined below), the Products
will be free from material defects in materials and workmanship. The foregoing warranty is subject to the proper
installation, operation and maintenance of the Products in accordance with installation instructions and the operating
manual supplied to Customer. Warranty claims must be made by Customer in writing within thirty (30) days of the
manifestation of a problem. Aeon Labs' sole obligation under the foregoing warranty is, at Aeon Labs' option, to repair,
replace or correct any such defect that was present at the time of delivery, or to remove the Products and to refund the
purchase price to Customer.
The "Warranty Period" begins on the date the Products is delivered and continues for 12 months.
Any repairs under this warranty must be conducted by an authorized Aeon Labs service representative and under
Aeon Labs' RMA policy. Any repairs conducted by unauthorized persons shall void this warranty.
Excluded from the warranty are problems due to accidents, acts of God, civil or military authority, civil disturbance, war,
strikes, fires, other catastrophes, misuse, misapplication, storage damage, negligence, electrical power problems, or
modification to the Products or its components.
Aeon Labs does not authorize any person or party to assume or create for it any other obligation or liability in
connection with the Products except as set forth herein.
Aeon Labs will pass on to Customer all manufacturers’ Material warranties to the extent that they are transferable, but
will not independently warrant any Material.
Customer must prepay shipping and transportation charges for returned Products, and insure the shipment or accept
the risk of loss or damage during such shipment and transportation. Aeon Labs will ship the repaired or replacement
products to Customer freight prepaid.
Customer shall indemnify, defend, and hold Aeon Labs and Aeon Labs' affiliates, shareholders, directors, officers,
employees, contractors, agents and other representatives harmless from all demands, claims, actions, causes of
action, proceedings, suits, assessments, losses, damages, liabilities, settlements, judgments, fines, penalties, interest,
costs and expenses (including fees and disbursements of counsel) of every kind (i) based upon personal injury or
death or injury to property to the extent any of the foregoing is proximately caused either by a defective product
(including strict liability in tort) or by the negligent or willful acts or omissions of Customer or its officers, employees,
subcontractors or agents, and/or (ii) arising from or relating to any actual or alleged infringement or misappropriation
of any patent, trademark, mask work, copyright, trade secret or any actual or alleged violation of any other intellectual
property rights arising from or in connection with the products, except to the extent that such infringement exists as a
result of Aeon Labs' manufacturing processes.
IN NO EVENT SHALL AEON LABS BE LIABLE FOR ANY INDIRECT, INCIDENTAL, PUNITIVE, SPECIAL OR CONSEQUENTIAL
DAMAGES, OR DAMAGES FOR LOSS OF PROFITS, REVENUE, OR USE INCURRED BY CUSTOMER OR ANY THIRD PARTY,
WHETHER IN AN ACTION IN CONTRACT, OR TORT, OR OTHERWISE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
AEON LABS' LIABILITY AND CUSTOMER'S EXCLUSIVE REMEDY FOR ANY CAUSE OF ACTION ARISING IN CONNECTION WITH
THIS AGREEMENT OR THE SALE OR USE OF THE PRODUCTS, WHETHER BASED ON NEGLIGENCE, STRICT LIABILITY, BREACH
OF WARRANTY, BREACH OF AGREEMENT, OR EQUITABLE PRINCIPLES, IS EXPRESSLY LIMITED TO, AT AEON LABS' OPTION,
REPLACEMENT OF, OR REPAYMENT OF THE PURCHASE PRICE FOR THAT PORTION OF PRODUCTS WITH RESPECT TO WHICH
DAMAGES ARE CLAIMED. ALL CLAIMS OF ANY KIND ARISING IN CONNECTION WITH THIS AGREEMENT OR THE SALE OR USE OF
PRODUCTS SHALL BE DEEMED WAIVED UNLESS MADE IN WRITING WITHIN THIRTY (30) DAYS FROM AEON LABS'S DELIVERY,
OR THE DATE FIXED FOR DELIVERY IN THE EVENT OF NONDELIVERY.
THE INDEMNITY AND WARRANTY IN ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER INDEMNITIES OR WARRANTIES,
WHETHER EXPRESS OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE.
FCC NOTICE (for USA)
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED
MODIFICATIONS TO THIS EQUIPMENT.SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE
EQUIPMENT.
STORE INDOORS WHEN NOT IN USE. SUITABLE FOR DRY LOCATIONS. DO NOT IMMERSE IN WATER. NOT FOR USE WHERE
DIRECTLY EXPOSED TO WATER.
This device may not cause harmful interference, and
This device must accept any interference received, including interference that may cause undesired operation. This
equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
1
2
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consul the dealer or an experienced radio/TV technician for help.
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities.
Contact your local government for information regarding the collection systems available.
Warning
Certifications (regional):
Z-Wave and Z-Wave Plus
are registered trademarks
of Sigma Designs and its
subsidiaries in the United
States and other countries
Version:501005600002-AA www.aeotec.com
6
C
C
C
C
C
System Operation.
Operation Notes.
1. USE THE MOBILE APPS TO CONTROL YOUR GARAGE DOOR, VIEW STATUS, AND SET CUSTOM RULES
2. THE GARAGE DOOR CONTROLLER WILL BEEP AND FLASH FOR FIVE SECONDS BEFORE THE DOOR MOVES
3. THE CONTROLLER WILL ACTIVATE THE DOOR OPENER AND OPEN OR CLOSE THE DOOR
4. THE MOBILE APP WILL SHOW THE NEW STATUS OF THE DOOR AFTER THE DOOR COMPLETES ITS CYCLE
1. The Alarm LED will blink and the Speaker System will sound for 5 seconds before the door opener is activated.
STAY CLEAR OF THE DOOR, AND DOOR OPENER. THEY ARE ABOUT TO MOVE!
2. If the door does not completely open or close after remote activation, you need to calibrate the Sensor again. For
detailed calibration steps, please refer to the “Configuration Parameter 34” in the engineering spec document of
Garage Door Controller.
Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the
equipment.
1. Use the Micro USB cable to connect Garage Door Controller to your PC host. Your PC host will detect the removable
storage after a few seconds, and then you will find it in the section of “Device with Removable Storage.
2. Double click the “CD Drive(G:) NEW” to open the storage.
3. Run the “MusicDownload.exe”.
4. Click the “Select Sound” tab on the menu, and then click the “Select Sound” button, which will open a new pop up
a window. Now you can select/choose the alarm sounds from your hard disk to update into Garage Door Controller’s
flash memory.
5. Click “Update” button and wait a few minutes to complete the updating.
Note:
1. Please do not disconnect the USB port until the update has completed.
2. The new ringtones will overwrite all of the old ringtones after the update is complete.
Download new alarm sounds to your Garage Door Controller from your PC host.