Parameter 51: Report which Buttons had been paired (Read Only)
Once Unpairing or Pairing Button Mode finishes, node will automatically send this configuration report via Lifeline to inform which Buttons had been paired. This
parameter does not restore to the default value when Siren is removed from the network or reset the factory settings.
Size: 1 Byte, Default Value: 0
Setting
Description
0
There is no paired Button.
1
#1 Button had been paired.
2
#2 Button had been paired.
3
#2 and #1 Button had been paired.
4
#3 Button had been paired.
5
#3 and #1 Button had been paired.
6
#3 and #2 Button had been paired.
7
#3, #2 and #1 Button had been paired.
Parameter 52: Get the information of #1 Button (Read Only)
This parameter does not restore to the default value when Sirene is removed from the network or reset the factory settings.
Size: 4 Byte, Default Value: 0
Setting
Description
0
#1 Button is unpaired.
1 - 2147483647
Information about #1 Button, including battery voltage (unit is mV) and software version.
Parameter 53: Get the information of #2 Button (Read Only)
This parameter does not restore to the default value when Siren is removed from the network or reset the factory settings.
Size: 4 Byte, Default Value: 0
Setting
Description
0
#2 Button is unpaired.
1 - 134217727
Information about #2 Button, including battery voltage (unit is mV) and software version.
Parameter 54: Get the information of #3 Button (Read Only)
This parameter does not restore to the default value when Siren is removed from the network or reset the factory settings.
Size: 4 Byte, Default Value: 0
Setting
Description
0
#3 Button is unpaired.
1 - 2147483647
Information about #3 Button, including battery voltage (unit is mV) and software version.
Parameter 96: Enable or Disable the ability that click the Action Button to stop a playing tone.
Size: 1 Byte, Default Value: 0
Setting
Description
0
Disable
1
Enable
Parameter 255: Factory Reset or Initialization (Write Only)
Parameter 51/52/53/54 will not restore the configuration settings to the default when Factory Reset or Initialization is performed.
Size: 4 Byte, Default Value: 0
Setting
Description
0
Initialization: Initialize all configuration parameters to default values.
1431655765
Factory Reset: Restore the product to factory settings and remove from the network.