![Aeotec AEO ZWA008-C User Manual Download Page 10](http://html.mh-extra.com/html/aeotec/aeo-zwa008-c/aeo-zwa008-c_user-manual_3049145010.webp)
31/07/2019
Door / Window 7 user guide : Aeotec Group
https://aeotec.freshdesk.com/support/solutions/articles/6000218764-door-windows-sensor-7-user-guide
10/10
Setting Description
0
Contact Scene Events disabled
1
Contact Scene Events enabled
Parameter 14: Tilt Sensor Functionality enable/disable.
Tilt Sensor functionality enable/disable.
Size: 1 Byte, Default Value: 1
Setting Description
0
Tilt Sensor disabled
1
Tilt Sensor Enabled
Parameter 15: Tilt sensitivity from V1.02 and higher
You can use this parameter to adjust the tilt sensitivity if the tilt is too low or too high.
Size: 1 Byte, Default Value: 50
Setting
Description
1 - 100
Tilt sensitivity