Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

1. Make sure a device is in factory reset state before including. In doubt exclude before include.
2. If inclusion still fails, check if both devices use the same frequency.
3. Remove all dead devices from associations. Otherwise you will see severe delays.
4. Never use sleeping battery devices without a central controller.
5. Dont poll FLIRS devices.
6. Make sure to have enough mains powered device to benefit from the meshing

Association - one device controls an other device

Z-Wave devices control other Z-Wave devices The relationship between one device controlling another device is called association In order to control a different

Summary of Contents for Aeotec

Page 1: ...es a reliable communication by recon rming every message two way communication and every mains powered node can act as a repeater for other nodes meshed network in case the receiver is not in direct w...

Page 2: ...ker should be turned off to perform these installation steps 1 Turn the main breaker off 2 Open the main circuit box panel 3 Clip one clamp of the meter around the incoming electricity cable that conn...

Page 3: ...es can also be removed from a network This process is called Exclusion Both processes are initiated by the primary controller of the Z Wave network This controller is turned into exclusion respective...

Page 4: ...uency 3 Remove all dead devices from associations Otherwise you will see severe delays 4 Never use sleeping battery devices without a central controller 5 Dont poll FLIRS devices 6 Make sure to have e...

Page 5: ...01 power energy detection mode Size 1 Byte Default Value 0 Setting Description 0 report power energy absolute value 1 report positive negative power report the algebraic sum energy 2 report positive n...

Page 6: ...ort Size 1 Byte Default Value 10 Setting Description 0 100 Valid value Parameter 13 Enable disable reporting Enable disable reporting CRC 16 Encapsulation Command Size 1 Byte Default Value 0 Setting D...

Page 7: ...Default Value 0 Setting Description 1 reset parameter 111 113 Parameter 111 Setting an automatic report interval Set the report intervall for Group 1 Size 4 Byte Default Value 0 Setting Description 1...

Page 8: ...dware Platform ZM5202 EAN 1220000015548 IP Class IP 44 Voltage 400V Load 60A Device Type Smart Meter Firmware Version 01 02 Z Wave Version 04 22 Certi cation ID ZC10 16105288 Z Wave Product Id 0x0086...

Page 9: ...ork Exclusion is the process of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled device Wakeup Noti cation is a special wire...

Reviews: