background image

 

Basic 

 

Clock 

 

Configuration 

 

Device Reset Locally 

 

Firmware Update Md V4 

 

Manufacturer Specific V2 

 

Meter V4 

 

Notification V4 

 

Powerlevel 

 

Protection V2 

 

Scene Activation 

 

Scene Actuator Conf 

 

Security 

 

Security 2 

 

Supervision 

 

Switch Binary 

 

Switch Color 

 

Switch Multilevel V2 

 

Transport Service V2 

 

Version V2 

 

Zwaveplus Info V2 

Controlled Command Classes 

 

Basic 

 

Notification V4 

 

Scene Activation 

 

Switch Binary 

Explanation of Z-Wave specific terms 

 

Controller

 — is a Z-Wave device with capabilities to manage the network. Controllers are typically 

Gateways,Remote Controls or battery operated wall controllers. 

 

Slave

 — is a Z-Wave device without capabilities to manage the network. Slaves can be sensors, actuators 

and even remote controls. 

 

Primary Controller

 — is the central organizer of the network. It must be a controller. There can be only 

one primary controller in a Z-Wave network. 

 

Inclusion

 — is the process of adding new Z-Wave devices into a network. 

 

Exclusion

 — is the process of removing Z-Wave devices from the network. 

 

Association

 — is a control relationship between a controlling device and a controlled device. 

 

Wakeup Notification

 — is a special wireless message issued by a Z-Wave device to announces that is 

able to communicate. 

 

Node Information Frame

 — is a special wireless message issued by a Z-Wave device to announce its 

capabilities and functions. 

 

Summary of Contents for Aeotec Smart Switch 7

Page 1: ...SmartStart inclusion No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network vicinity 2 Indicator Light will become...

Page 2: ...r more information about Z Wave technology devices white papers etc please refer to www z wave info Product Description The Aeotec Smart Switch 7 is an elegant appearance small size easy to use Smart...

Page 3: ...Press Action Button 2 times quickly Product Usage Button Presses and LED reaction Button Press Function when released LED Reaction Power On Unpaired from the network Paired into the network Breathes...

Page 4: ...ent happens all devices stored in the respective association group will receive the same wireless command wireless command typically a Basic Set Command Association Groups Group Number Maximum Nodes D...

Page 5: ...bit field where each individual bit can be set or reset A graphical configuration tool SHOULD present this parameter as a series of checkboxes Please refer to the manual for more details about suppor...

Page 6: ...e of power out Size 1 Byte Default Value 0 Setting Description 0 Last status 1 Switch is on 2 Switch is off Parameter 80 Configure what command will be sent via Lifeline when switch state has changed...

Page 7: ...ption 0 Disable 1 100 0 1 10A Unit is 0 1A Parameter 101 Configure which meter reading will be periodically report via Lifeline The format of the parameter is Bit field Checkboxes The parameter MUST b...

Page 8: ...10A Device Type On Off Power Switch Network Operation Always On Slave Z Wave Version 6 81 03 Certification ID ZC10 19066544 Z Wave Product Id 0x0371 0x0003 0x00AF Outdoor Use ok Sensors CurrentPowerV...

Page 9: ...perated wall controllers Slave is a Z Wave device without capabilities to manage the network Slaves can be sensors actuators and even remote controls Primary Controller is the central organizer of the...