background image

Setting 

Description 

1431655765 

Factory Reset: Restore the product to factory settings and remove from the network. 

Initialization: Initialize all configuration parameters to default values. 

Technical Data 

Dimensions 

42 x 42 x 70 mm 

Weight 

56 gr 

Hardware Platform 

ZM5101 

EAN 

1220000016415 

IP Class 

IP 20 

Voltage 

230 V 

Load 

10A 

Device Type 

On/Off Power Switch 

Network Operation 

Always On Slave 

Z-Wave Version 

6.81.03 

Certification ID 

ZC10-19066544 

Z-Wave Product Id 

0x0371.0x0003.0x00AF 

Outdoor Use 

ok 

Sensors 

CurrentPowerVoltage 

Supported Notification Types 

Power ManagementSystem 

Z-Wave Scene Type 

Scene 

Color 

White 

Firmware Updatable 

Updatable by Consumer by RF 

Supported Meter Type 

Electric Energy 

Frequency 

Europe - 868,4 Mhz 

Maximum transmission power 

5 mW 

 

 

Supported Command Classes 

 

Application Status 

 

Association Grp Info 

 

Association V2 

Summary of Contents for Aeotec Smart Switch 7

Page 1: ...SmartStart inclusion No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network vicinity 2 Indicator Light will become...

Page 2: ...r more information about Z Wave technology devices white papers etc please refer to www z wave info Product Description The Aeotec Smart Switch 7 is an elegant appearance small size easy to use Smart...

Page 3: ...Press Action Button 2 times quickly Product Usage Button Presses and LED reaction Button Press Function when released LED Reaction Power On Unpaired from the network Paired into the network Breathes...

Page 4: ...ent happens all devices stored in the respective association group will receive the same wireless command wireless command typically a Basic Set Command Association Groups Group Number Maximum Nodes D...

Page 5: ...bit field where each individual bit can be set or reset A graphical configuration tool SHOULD present this parameter as a series of checkboxes Please refer to the manual for more details about suppor...

Page 6: ...e of power out Size 1 Byte Default Value 0 Setting Description 0 Last status 1 Switch is on 2 Switch is off Parameter 80 Configure what command will be sent via Lifeline when switch state has changed...

Page 7: ...ption 0 Disable 1 100 0 1 10A Unit is 0 1A Parameter 101 Configure which meter reading will be periodically report via Lifeline The format of the parameter is Bit field Checkboxes The parameter MUST b...

Page 8: ...10A Device Type On Off Power Switch Network Operation Always On Slave Z Wave Version 6 81 03 Certification ID ZC10 19066544 Z Wave Product Id 0x0371 0x0003 0x00AF Outdoor Use ok Sensors CurrentPowerV...

Page 9: ...perated wall controllers Slave is a Z Wave device without capabilities to manage the network Slaves can be sensors actuators and even remote controls Primary Controller is the central organizer of the...