Function of Button- or (Parameter Number 47, Parameter Size 1) Define the function
of Button- and .
Value
Description
0
Pressing it once, the and Button- are defined to be used to increase and
decrease the volume. Press and hold it, the and Button- are defined to be the
control item of Next and Previous. (Default)
1
Pressing it once, the and Button- are defined to be the control item of Next
and Previous. Press and hold it, the and Button- are defined to be used to
increase and decrease the volume.
Notifications to Associated Devices (Parameter Number 80, Parameter Size 1) Enable/Disable
to send notifications to associated devices.
Value
Description
0
Send Nothing (Disabled)
1
Send HAIL Command
2
Send BARRIER OPERATOR Report Command (Default)
Pair Sensor with Garage Door Controller (Parameter Number 241, Parameter Size 4) Send
Configuration Set: Value=0x55555501, which will trigger to start the pairing of Sensor
(installed on the top of the garage door), at this time, the Network LED on the Garage Door
Controller will blink slowly and then short press Temper Switch back of the Sensor. If pairing
is successful, the Network LED will stop blinking and the Garage Door Controller will send
the configuration report with value=0x01FF to primary controller/gateway. Otherwise, repeat
the operation. Note: 1. If you do not press the Temper Switch when starting the pairing mode,
the pairing status will keep for 8 second and - 4 9 then exit the pairing status automatically. 2.
The Sensor has been paired with the Garage Door Controller after factory.
Value
Description
1431655681 Start the Sensor pairing mode.
Lock Configuration (Parameter Number 252, Parameter Size 1) Enable/Disable Lock
Configuration
Value
Description
0
All configuration parameters are configurable. (Default)
1
All configuration parameters are not configurable (Locked).
Reset to Default Factory Setting (Parameter Number 255, Parameter Size 4)
Value
Description
1
Reset all configuration parameters to default setting. (Default)
1431655765
Reset the product to default factory setting and be excluded from the Z-wave
network.
Command Classes
Supported Command Classes
•
Basic (version 1)
•
Binary Switch (version 1)
•
Association Group Information (version 1)
•
Z-Wave Plus Information (version 2)
•
Configuration (version 1)