4.
INSTALLATION
Warning! These operations can only be performed by qualified professionals for this service.
4.1
Place
of
installation
Note: The use of a central vacuum power unit presupposes the existence of a network of piping
suction installed by qualified technicians who evaluate the most appropriate location.
In buildings with several floors locate the machine is the lowest point of the building. The machine
must be installed in places not exposed to weather, changes in humidity and over-temperature.
Choose an airy place away from heat sources such as stoves and heaters. Provides a well-lit space
around the machine to facilitate the operations of maintenance and repair. In case of doubt ask for
advice to the service facility of the manufacturer.
4.2
Setting
the
central
A central vacuum power unit should be fixed on a stable and permanent way to a wall using the fixing
plate and bushings appropriate provided considering that the total weight that it has to sustain can get
seven to eight times the weight of the machine, with the container of the dust full.
The height to the ground should allow easy intervention to dump the receiver of the dust and replace
the filter.
To perform the operation is necessary: (See
FIG. C
– page 4)
1 – Mark the drilling points using the supplied fixing plate;
2 – Screw the plate to the wall;
3 – Hook the machine to the fixing plate.
4.3
Connecting
to
the
network
of
pipes
1 - Connect the machine to the suction tube.
2 - Connect the machine to the tube of air discharge.
3 - Paste the silencer on the discharge tube near the exhaust vent.
4.4
Electrical
Connection
IMPORTANT! = Before performing any operation turn off the power.
WARNING! = The installation must be performed exclusively by qualified persons!
Before making the electrical connection check if the voltage of power corresponds to the power of the
central vacuum power unit.
Connect the signal cable activation of low voltage (12V).
The manufacturer is not responsible for damage to persons and / or things that derives from a
connection to an electrical installation not in accordance with the standards.