background image

ELECTRICAL SPECIFICATIONS

 

Nominal Range: 

200 A

 

Measurement Range: 

0.5 to 240 A AC

 

Transformation Ratio: 

1000:1

Output Signal: 

1 mA/A on 1

Ω

Accuracy and Phase Shift*: 

Accuracy:  0.5 to 10 A:  3.0% Reading ± 0.5 A 

10 to 40 A:  2.5% Reading ± 0.5 A 

40 to 100 A:  2.0% Reading ± 0.5 A 

100 to 240 A:  1.0% Reading ± 0.5 A 

Phase Shift:  0.5 to 10 A:  Not Specified 

10 to 40 A: 

 5° 

40 to 100 A: 

 3° 

100 to 240 A: 

 2.5° 

(*Reference conditions:18°C to 28°C, 20 to 75% RH, 

external magnetic field < 40 A/m, 48 to 65 Hz sine 

wave, distortion factor less than 1%, no DC 

component, no external current carrying conductor, 

test sample centered.) Load impedance 1

Ω

Overload:

240 A for 10 min ON, 30 min OFF

 

Frequency Range: 

40 to 10 kHz

 

Limit Operating Conditions: 

200 A permanently to 1 kHz 
Derating above 3 kHz: 200 A x (1/0.333 F), F in kHz 

Crest Factor: 

3 @ 200 Arms with an error (due to CF) of 4% 

Working Voltage: 

600 Vrms 

Common Mode Voltage: 

600 Vrms

 

Influence of Adjacent Conductor: 

< 15 mA/A at 50 Hz 

Influence of DC (< 20 A) on AC signal: 

< 5% 

Influence of Conductor Position in Jaw:  

0.5% of mA output @ 50/60 Hz 

Influence of Load:  

< 3% of mA output from 40 Hz to 1 kHz 
< 12% of mA output from 1 kHz to 10 kHz 

Influence of Temperature: 

 150 ppm/°K, or 0.15% of mA output per 10°K 

Influence of Humidity (10 - 90% RH): 

 0.2% of mA output per 10°K @ 18°C to 28°C 

MECHANICAL SPECIFICATIONS

 

Operating Temperature: 

14° to 131°F (-10° to +55°C)  

Storage Temperature: 

-40° to 158°F  (-40° to +70°C) 

Operating Relative Humidity: 

10-35°C 85% RH (without roll-off above 35°C) 

Maximum Cable Diameter: 

One Ø 0.78” (20 mm), bus bar 20 x 5 mm 

Case Protection: 

IP 40 (IEC 529)

 

Drop Test: 

Test per IEC 68-2-32: 1.0 m drop on 38 mm of 
Oak on concrete. 

Mechanical Shock: 

Test per IEC 68-2-27 

Vibration: 

Test per IEC 68-2-6 

Dimensions: 

5.47 x 2.00 x 1.18"  (139 x 51 x 30 mm) 

Weight: 

180 g (6.5 oz)

 

Polycarbonate Material: 

Jaws: Polycarbonate with 10% fiberglass charge, 

  Red UL 94 V0 

Case: Polycarbonate 920A Gray 

Opening Operations - Life: 

> 50,000 

Output: 

MN210:

 Two standard safety banana jacks (4 mm) 

MN211: 

Double/reinforced insulated 5 ft. (1.5 m) 

lead with safety 4mm banana plug  

SAFETY SPECIFICATIONS 

Electrical: 

Double insulation or reinforced insulation between 
the primary or secondary and the outer case of the 
handle conforms to IEC 1010-2-32. 

Common Mode Voltage: 

600 V Category III, Pollution Degree 2 

Dielectric Strength: 

5550 V, 50/60 Hz between primary, secondary  
and the outer case of the handle 

Electromagnetic Compatibility: 

EN 50081-1 Class B 
EN 50082-2 Electrostatic discharge 
   IEC 1000-4-2 
Radiated field IEC 1000-4-3 
Fast transients IEC 1000-4-4 
Magnetic field at 50/60 Hz IEC 1000-4-8 

ORDERING INFORMATION

 

AC Current Probe MN210 ................. Cat #2115.72 

AC Current Probe MN211 ................. Cat #2115.73 

Both models include a user manual and a 
product warranty and registration card. 

Accessories: 

Leads, set of 2, 5 ft safety (1000V) .....

Cat #2111.29 

Banana plug adapter 
(to nonrecessed plug) ........................

Cat #1017.45

 

2.56"

 (65 mm)

5.47"

 (139 mm)

.83"

 (21 mm)

Black

Red

.73"

2.00"

 (51 mm)

(18.5 mm)

.1.18"     

(30 mm)

MN211

MN210

E192383

Reviews: