background image

CURRENT PROBE - JM810A DRAWING

ELECTRICAL SPECIFICATIONS

Current Range:

1 to 2000 A

ac

, continuous cycle for the full 

temperature range

Transformation Ratio:

2000:2

Output Signal:

1 mA

ac 

/ A

ac

 (2 A at 2000 A)

Accuracy and Phase Shift*:

Primary Current 100 A 400 A 2000 A
Accuracy %

2%

1%

0.5%

Phase shift

1.5°

0.75°

0.5°

*(Reference conditions: 23°C ± 3°C, 20 to 

85% RH, 48 to 65 Hz, external magnetic 

field <40 A/m, no DC component, no 

external current carrying conductor, test 

sample centered.)
Load impedance 0.5 Ω.

Overload:

 2400 A for 10 min

Accuracy:

 Per IEC 185-26-27

 

Class 0.5 from 48 to 1000 Hz

Frequency Range:

30 Hz to 5 kHz; current derating above

1 kHz for continuous use.

Load Impedance:

 ≤ 1 Ω

Working Voltage:

 600 Vac

Common Mode Voltage:

 600 Vac

Influence of Adjacent Conductor:

0.005 A / A

ac

Influence of Conductor in Jaw Opening: 

1% ± 0.1 A of reading

Reviews: