background image

FlexProbe

®

 - Flexible AC Current Probe

 

3

 

CHAPTER 1

INTRODUCTION

  WARNING  

  Read  the  instruction  manual  completely  and  follow  all  the  safety 

information before attempting to use or service this instrument.

• 

Wear protective clothing and gloves as required.

• 

Use  caution  on  any  circuit:  potentially  high  voltages  and  currents 

may be present and may pose a shock hazard.

• 

Read  the  safety  specifications  section  prior  to  using  the  current 

probe. Never exceed the maximum voltage ratings given.

• 

Safety is the responsibility of the operator. The FlexProbe

®

 must be 

used  only  by  qualified  personnel  using  applicable  safety  precau

-

tions.

• 

ALWAYS  de-energize  the  circuit  before  wrapping  the  FlexProbe

®

 

around bare conductors, bus bars, or near live parts. Do not wrap on 

live conductors.

• 

ALWAYS connect the electronic module to the display device before 

wrapping the FlexProbe

®

 around the sample being tested.

• 

ALWAYS inspect the module, sensor, sensor cable, and output termi

-

nals prior to use. Replace any defective parts immediately. Use only 

factory parts.

• 

NEVER  use  the  FlexProbe

®

  on  electrical  conductors  rated  above 

1000V CAT III and 600V CAT IV.

1.1 

International Electrical Symbols

This symbol signifies that the instrument is protected by double or reinforced 

insulation.
This symbol on the instrument indicates a WARNING and that the operator must 

refer to the user manual for instructions before operating the instrument. In this 

manual, the symbol preceding instructions indicates that if the instructions are 

not followed, bodily injury, installation/sample and product damage may result.
Risk of electric shock. The voltage at the parts marked with this symbol may be 

dangerous.
This symbol refers to a type B current sensor. Do not apply around or remove from 

HAZARDOUS LIVE conductors without additional protective means (de-energizing 

the circuit or wearing protective clothing suitable for high voltage work).

 

In conformity with WEEE 2002/96/EC

www.

ShopAEMC

.com

Shop for AEMC products online at:

1.888.610.7664

Summary of Contents for FlexProbe 24-3001

Page 1: ...IBLE AC CURRENT PROBE FlexProbe 24 3001 E N G L I S H User Manual I N S T R U M E N T S CAT III 1000V 300A 3000A OFF ON OL FlexProbe 24 3002 www ShopAEMC com Shop for AEMC products online at 1 888 610...

Page 2: ...www ShopAEMC com Shop for AEMC products online at 1 888 610 7664...

Page 3: ...hase or obtained by returning the instrument to our repair and calibration facility for a nominal charge The recommended calibration interval for this instrument is 12 months and begins on the date of...

Page 4: ...2 1 Description 5 2 2 General Features 6 2 3 FlexProbe 24 3001 Features 7 3 SPECIFICATIONS 8 3 1 Electrical 8 3 2 Environmental 9 3 3 Mechanical Specifications 9 3 4 Safety Specifications 10 4 OPERAT...

Page 5: ...ct the module sensor sensor cable and output termi nals prior to use Replace any defective parts immediately Use only factory parts NEVER use the FlexProbe on electrical conductors rated above 1000V C...

Page 6: ...y overcurrent protection devices ripple control units or meters 1 3 Receiving Your Shipment Upon receiving your shipment make sure that the contents are consis tent with the packing list Notify your d...

Page 7: ...typically associated with flexible sensors The FlexProbe is lightweight It does not use magnetic cores like standard transformers The transformation principle is based on an air core It pres ents virt...

Page 8: ...nge LED for measurement circuitry EN 61010 1000V CAT III 600V CAT IV Waterproof sensor 9V battery for typical 150 hour continuous operations Shape Memory for custom pre shaping of sensor before use no...

Page 9: ...robe 24 3002 1 2 3 6 4 5 8 7 1 Flexible sensor 0 5 12 5mm 2 Range selection switch 3 Power ON indicator Green LED 4 Overload indicator Red LED 5 Electronic module 6 Double insulated 14 36cm lead with...

Page 10: ...r 1 of Reading 500mA Crest Factor 4 5 Phase Shift 0 7 at 50 or 60Hz Frequency Range 40 to 5kHz Residual Noise When I Measured 0 200mArms Working Voltage 1000Vrms CAT III 600V CAT IV Common Mode Voltag...

Page 11: ...Sensor 24 1 610 x 25mm Color Sensor Red with black connector Dimensions Electronic Module 4 9 x 2 5 x 1 1 124 x 64 x 28mm Color Electronic Module Dark gray Weight 1 1 lb 0 5kg Output Double insulated...

Page 12: ...dle per EN 61010 EN 61010 1000V CAT III 600V CAT IV Pollution Degree 2 Electromagnetic Compatibility EN 50081 1 Class B EN 50082 2 Electrostatic discharge IEC 1000 4 2 Radiated Field IEC 1000 4 3 Fast...

Page 13: ...eed specified current range for the output Do not use on selected range if Overload LED goes on 4 Example a Read the DMM displayed value 2 59V b Determine the range and output used on the FlexProbe 0...

Page 14: ...on and accuracy when measuring low mVAC For best accuracy center the FlexProbe around the conductor to be measured To increase the sensitivity or measure on low cur rents the FlexProbe may be wrapped...

Page 15: ...nge 250A I N S T R U M E N T S CAT III 1000V 300A 3000A OFF ON OL FlexProbe 24 3002 ACV DCV COM 250 0MV I N S T R U M E N T S CAT III 1000V 300A 3000A OFF ON OL FlexProbe 24 3002 Double the turns to d...

Page 16: ...n page 2 5 1 Changing the Battery If the power ON indicator green LED blinks or does not light up replace the battery Disconnect the instrument from any source of electricity To replace the battery op...

Page 17: ...www ShopAEMC com Shop for AEMC products online at 1 888 610 7664...

Page 18: ...we have your warranty registration information on file or a proof of purchase AEMC Instruments will at its option repair or replace the faulty material Warranty Repairs What you must do to return an I...

Page 19: ...www ShopAEMC com Shop for AEMC products online at 1 888 610 7664...

Page 20: ...01 15 99 MAN 100272 v8 Chauvin Arnoux Inc d b a AEMC Instruments www ShopAEMC com Shop for AEMC products online at 1 888 610 7664...

Reviews: