CONTENTS

1 -

Presentation ............................................................................. 3

2 -

Description ............................................................................... 4

3 -

DC and AC voltage (V) ............................................................ 5

4 -

Frequency (Hz) ....................................................................... 6

5 -

Continuity and resistance (

 ) ......................................... 6

6 -

Diode test (

) ........................................................................ 7

7 -

Capacitance (   ) ................................................................... 8

8 -

DC and AC current (A and mA) ............................................... 8

9 -

General specifications ............................................................ 9

10 -

To order (accessories) ........................................................ 10

11 -

Warranty ............................................................................... 10

12 -

Maintenance ......................................................................... 10
Technical and Sales Assistance ........................................... 11

1 - PRESENTATION

The C.A 5230 multimeter is designed for the daily needs of
professionals in electricity.
- true rms measurement (RMS)
- digital 4000 counts and 42 segment bargraph
- automatic or manual range selection
- auto off after 30 minutes without action on a control or function
- possibility of permanent operation (see HOLD)

Various measurement accessories broaden the scope of application
or provide the multimeter with new functions.
See the list of accessories and references on the “To Order” page
(Documentation upon request).

Note :

 Always use accessories suitable for the voltage and the

voltage surge category of the circuit to be measured (as per IEC
1010).

Summary of Contents for C.A 5230

Page 1: ...r manual DigitalMultimeter Model C A 5230 MULTIMETER Hz V V OFF mA 10A M I N MAX RANGE HOLD ZERO 10A 500mA FUSED 10A max FUSED C A 5230 COM 600V CAT III MAX ZERO n u F Mk Hz HOLD 30 20 10 0 40 RMS MUL...

Page 2: ...instrument and invalidation of the warranty Fuse 0 5A HBC 500V min 10kA 6 3 x 32mm Fuse 12A HBC 600V min 300kA 10 3 x 38mm Never use on voltage to earth circuits above 600V with a voltage surge categ...

Page 3: ...rofessionals in electricity true rms measurement RMS digital 4000 counts and 42 segment bargraph automatic or manual range selection auto off after 30 minutes without action on a control or function p...

Page 4: ...measurement HOLD On capacitancemeter function zero reset by press without releasing Permanent operation possibility of suppressing auto off by pressing this button without releasing before operating...

Page 5: ...lead for the 10AAC DC ranges 3 DC AND AC VOLTAGE Connect the leads to the multimeter and connect it in parallel to the circuit to be tested Place the selector switch on the voltmeter function VAC DC A...

Page 6: ...tton for this function selects the triggering threshold 10mV for 100Hz 1kHz and 10kHz ranges 400mV for 100kHz and 400kHz ranges 2 Note Ifthefrequencyappliedis99 99kHz thedecimalpointoscillatesbetween9...

Page 7: ...Connect the leads to the multimeter and to the terminals of the component to be tested Place the selector switch on the function in forward direction the display gives the value of the junction in vo...

Page 8: ...ges manually MIN MAX to read the min or max values to light the display 4nF 40nF 400nF 4 F 40 F 1 Resolution 1pF 10pF 100pF 1nF 10nF Accuracy 2 R 150cts 2 of reading 8cts Protection 500V mns 750 peak...

Page 9: ...6 F 22 500 h with alkaline battery type 6 LF22 Low battery indication Auto off after 30 minutes Note Switch on again via the OFF position 9 3 Buzzer Continuous beep for the continuity test Intermitte...

Page 10: ...el MR410 400AAC 600ADC Cat 1200 70 AmpFLEX model 1000 24 1 1 1000AAC Cat 2112 39 Replacement leads Cat 2118 66 Soft carrying case Cat 2118 65 Replacement shockproof case Cat 2980 15 Fuse set of 10 0 5...

Page 11: ...our factory service center at one year intervals for recalibration or as required by other standards For instrument repair and or calibration please call our factory toll free at 800 945 AEMC 800 945...

Reviews: