AC Current Oscilloscope Probe Model SR661

 

3

 

1.1 

International Electrical Symbols

This symbol signifies that the instrument is protected by double or rein-

forced insulation.
This symbol on the instrument indicates a WARNING and that the operator 

must refer to the user manual for instructions before operating the 

instrument. In this manual, the symbol preceding instructions indicates that 

if the instructions are not followed, bodily injury, installation/sample and 

product damage may result.
Risk of electric shock. The voltage at the parts marked with this symbol may 

be dangerous.
This symbol refers to a type A current sensor. This symbol signifies that 

application around and removal from HAZARDOUS LIVE conductors is per-

mitted.
Probe fitted with an electronic output limiter providing protection against 

voltage surges caused by the accidental opening of the probe secondary 

circuit to 30V max. peak.

 

In conformity with WEEE 2002/96/EC.

1.2 

Definition of Measurement Categories

CAT II: 

For  measurements  performed  on  circuits  directly  connected  to 

the electrical distribution system. Examples are measurements 

on household appliances or portable tools.

CAT III:

  For  measurements  performed  in  the  building  installation  at 

the  distribution  level  such  as  on  hardwired  equipment  in  fixed 

installation and circuit breakers.

CAT IV: 

For  measurements  performed  at  the  primary  electrical  supply 

(<1000V)  such  as  on  primary  overcurrent  protection  devices, 

ripple control units, or meters.

1.3 

Receiving Your Shipment

Upon receiving your shipment, make sure that the contents are consistent 

with the packing list. Notify your distributor of any missing items. If the 

equipment appears to be damaged, file a claim immediately with the car

-

rier and notify your distributor at once, giving a detailed description of any 

damage. Save the damaged packing container to substantiate your claim.

Summary of Contents for 2113.49

Page 1: ...AC CURRENT OSCILLOSCOPE PROBE SR661 E N G L I S H User Manual...

Page 2: ...the instrument to our repair and calibration facility for a nominal charge The recommended calibration interval for this instrument is 12 months and begins on the date of receipt by the customer For r...

Page 3: ...URES 5 2 1 Description 5 2 2 Compatibility 5 2 3 Features 6 3 SPECIFICATIONS 7 3 1 Electrical Specifications 7 3 2 Mechanical Specifications 8 3 3 Environmental Specifications 9 3 4 Safety Specificati...

Page 4: ...ot use the probe if damaged Always connect the current probe to the measuring device before it is connected around the conductor Do not use on non insulated conductor with a potential to ground greate...

Page 5: ...the accidental opening of the probe secondary circuit to 30V max peak In conformity with WEEE 2002 96 EC 1 2 Definition of Measurement Categories CAT II For measurements performed on circuits directl...

Page 6: ...lloscope Probe Model SR661 1 4 Ordering Information AC Current Oscilloscope Probe Model SR661 Cat 2113 49 Includes a user manual 1 4 1 Accessories and Replacement Parts Male Banana Female BNC Adaptor...

Page 7: ...to 1000Arms 1Hz to 100kHz with current derating without breaking into the circuit A passive filter eliminates noise ring on rapid rising di dt waveforms and ensures accurate screen displays The probe...

Page 8: ...mm 3 90 99 mm 2 13 54 1mm 1 2 3 5 4 6 1 Jaw opening of 2 25 2 Maximum dimension of conduct is 2 13 54mm 3 Tactical Barrier Always keep hands below this barrier at all times 4 Arrow indicates directio...

Page 9: ...peak Output Signal mV output signal 2V peak max 100mV A 10mA to 20A peak 10mV A 0 1A to 200A peak 1mV A 1A to 2000A peak 1mV A 1V at 1000A Range Accuracy Phase Shift 1 to 50A 1 1mV N A 50 to 200A 3 2...

Page 10: ...10 to 1000 Hz 1 of Reading From 1 to 10kHz 2 of Reading From 10 to 50kHz 10 of Reading From 50 to 100kHz 3 dB Range 10mV A From 10 to 1000 Hz 5 of Reading From 1 to 10kHz 3 of Reading From 10 to 50kHz...

Page 11: ...Humidity 0 to 85 35 C Influence of Temperature 0 15 10K Influence of Humidity 10 to 90 0 1 3 4 Safety Specifications E192383 Electrical Double insulation or reinforced insulation between the primary...

Page 12: ...1mV A Range 10 100 1000 10 000 100 000 4 00 5 00 1 00 0 00 1 00 2 00 3 00 10 100 1000 10 000 100 000 35 00 40 00 5 00 15 00 20 00 25 00 30 00 10 00 5 00 0 00 Accuracy in Phase in Frequency Hz Frequen...

Page 13: ...100 1000 10 000 100 000 25 00 30 00 0 00 5 00 10 00 15 00 20 00 10 100 1000 10 000 100 000 60 00 70 00 10 00 20 00 30 00 40 00 50 00 10 00 0 00 5 00 Accuracy in Phase in 1 A 5 A 1 A 5 A Frequency Hz...

Page 14: ...0 100 000 10 100 1000 10 000 100 000 40 00 45 00 15 00 20 00 25 00 30 00 35 00 5 00 10 00 5 00 0 00 40 00 50 00 10 00 0 00 10 00 20 00 30 00 20 00 30 00 40 00 0 1 A 0 5 A 0 1 A 0 5 A Accuracy in Phase...

Page 15: ...he current flowing directly on your oscilloscope Remember to unclamp the probe from the conductor before discon necting it from your meter or instrument You may also use your oscilloscope to amplify t...

Page 16: ...er or other foreign substances into the case Disconnect the unit from all circuits and test cables before open ing the case Use caution with metallic tools that may short battery packs power supplies...

Page 17: ...T Includes calibration certificate plus recorded calibration data Ship To Chauvin Arnoux Inc d b a AEMC Instruments 15 Faraday Drive Dover NH 03820 USA Phone 800 945 2362 Ext 360 603 749 6434 Ext 360...

Page 18: ...NE AT www aemc com Warranty Repairs What you must do to return an Instrument for Warranty Repair First request a Customer Service Authorization Number CSA by phone or by fax from our Service Departmen...

Page 19: ...AC Current Oscilloscope Probe Model SR661 17 Notes...

Page 20: ...10 17 99 MAN 100130 v13 Chauvin Arnoux Inc d b a AEMC Instruments 15 Faraday Drive Dover NH 03820 USA Phone 603 749 6434 Fax 603 742 2346 www aemc com...