16
2.4
BUTTON
2.4.1 Normal Mode
This button activates the detection of the MAX, MIN, PEAK+ and PEAK- values of
the measurements made.
Max and Min are the extreme mean values in DC and the extreme RMS values in
AC. Peak+ is the maximum instantaneous peak and Peak- is the minimum
instantaneous peak.
NOTE:
In this mode, the Auto Power Off function of the device is automatically
disabled. The
symbol is displayed on the screen.
Successive presses on
Function
short
First press:
Activates detection of the
MAX/MIN/PEAK values
Second press:
Displays the MAX, MIN,
PEAK+ or PEAK- value successively
Third press:
Returns to the display of the
present measurement without exiting from
the mode (the values already detected are
not erased)
NOTE:
The MAX, MIN, PEAK+ or PEAK-
symbols are all displayed, but only the
symbol of the measurement selected
blinks.
Example:
If MIN has been selected, MIN
blinks and MAX, PEAK+, PEAK- are lit
steadily.
- Activates the detection of MAX/MIN
values
- Displays the MAX or MIN value
successively
- Returns to the display of the present
measurement without exiting from the
mode (the values already detected are
not erased).
long (> 2 sec)
- Exits the MAX/MIN/PEAK mode. The
values previously recorded are then
erased.
NOTE:
If the HOLD function is enabled, it
is not possible to exit from the
MAX/MIN/PEAK mode. The HOLD
function must first be disabled first.
NOTE
:
ΔREL function
can be used with the functions of the MAX/MIN/PEAK mode.