AA36-100 Digital ICS Tie Line Adapter
SM58 Installation and Operation Manual
April 15, 2012 Rev: 5.00
Page 2-4
ENG-FORM: 805-0100.DOTX
CONFIDENTIAL AND PROPRIETARY TO ANODYNE ELECTRONICS MANUFACTURING CORP.
2.3.5.5
ICS TIE I/P switch
This four-position rotary switch is used for selecting the input level for the universal bi-directional ICS tie
line. The rated inputs are NAT Tie Line, Andrea, Gemelli and dB Systems. For example, if the NAT tie line
is to be used, this switch must be set to position 0. If dB System’s intercoms are attached, the switch must
be set to position 3.
2.3.5.6
OUTPUT IMPED. HI switch
This four-position rotary switch is used for selecting the high-side output impedance for the universal bi-
directional ICS tie line. The rated outputs are NAT Tie Line, Andrea, Gemelli and dB Systems. For example, if
the NAT
tie line is to be used, this switch must be set to position 0. If dB System’s intercoms are attached, the
switch must be set to position 3.
Note:
Both output impedance switches must be set to the same position.
2.3.5.7
OUTPUT IMPED. LO switch
This four-position rotary switch is used for selecting the low-side output impedance for the universal bi-
directional ICS tie line. The rated outputs are NAT Tie Line, Andrea, Gemelli and dB Systems. For
example, if the NAT tie line is to be used, this swi
tch must be set to position 0. If dB System’s intercoms
are attached, the switch must be set to position 3.
Note:
Both output impedance switches must be set to the same position.
2.3.5.8
ICS TIE O/P switch
This four-position rotary switch is used for selecting the output level for the universal bi-directional ICS tie
line. The rated outputs are NAT Tie Line, Andrea, Gemelli and dB Systems. For example, if the NAT tie
line is to be used, this switch must be set to position 0. If dB System’s intercoms are
attached, the switch
must be set to position 3.
2.3.5.9 MODE
CONTROL
This ten-position rotary switch is used to select between the Universal bi-directional ICS tie line and the
Universal unidirectional ICS tie line. Only one is active at a time.
2.3.5.10 UNIVERSAL
AEM
LOAD
Switch
This two-position rotary switch switches in the correct impedance for the selected ICS tie line on the
Universal ICS tie line.
2.3.6 Mechanical
Installation
The AA36-100 Digital ICS Tie Line Adapter can be installed in any attitude, using either the AA36-100-
IKC or AA36-100-IKS Installation kits (refer to Section 2.5 for details).
For proper installation, refer to
Mechanical Installation
drawing (AA36\100\922-0).