background image

9

2/5/2019 -  DOCUMENT NUMBER: 10-2226

© 2019 AEM Performance Electronics

30-2226 6 Channel CAN Sensor Module

Device Pinout

Pin

Name

Function

1

12V Battery Power (+)

Primary ignition/battery power input

2

Battery Ground (-)

Primary ignition/battery ground input

3

 / CANH

AEMnet / CAN bus output

4

AEMnet- / CANL

AEMnet / CAN bus Output

5

Analog 1

Temperature / thermistor input, 2200 Ohm 5V pull-up

6

Analog 2

Temperature / thermistor input, 2200 Ohm 5V pull-up

7

Analog 3

0-5V Analog input, 100k Ohm 5V pull-up

8

Analog 4

0-5V Analog input, 100k Ohm 5V pull-up

9

Tachometer

Engine speed input (negative coil terminal) 12V pull-up

10

Fuel Level

0 - 250 Ohm fuel level sensor input

11

Sensor Ground

Dedicated sensor ground

12

5V Sensor Power

5V sensor reference power output

Analog Inputs 1 - 2

These inputs have a 2200 Ohm 5V pull-up resistor and are suitable for two-wire thermistor temperature sensors.  It is not
recommended to connect these inputs to pre-existing/OEM sensors that are already connected to a factory ECU or
logging device.  Please refer to the table below for connection examples.

New / Added

Sensors

5V Sensor

Power

Sensor

Signal

Sensor

Ground

Examples

Two wire temperature

û

ü

ü

Intake, coolant/oil temperature, etc

ü

= Connect

û

=Don't connect

! = Read Notes

CAN Output

The measured resistance will be output via CAN and will have to be scaled to temperature in the receiving device.  A
thermistor's resistance varies non-linearly with temperature and thus the receiving device will likely require a look-up table
to properly log or display temperature.  The AEM CD series of dashes have this capability; please refer to the appropriate
documentation.

Summary of Contents for 30-2226

Page 1: ...modates a wide variety of sensors and is housed in a sealed IP67 weather resistant enclosure Sturdy construction protected inputs and simple configuration make this the perfect entry point to get ever...

Page 2: ...he shield should only be grounded drained on one end of the wiring harness CAN wiring should utilized twisted pairs 1 TPI shielding is recommended The Sensor Module s sensor ground should be at the sa...

Page 3: ...are objects that obtain information from one or more sources or other outputs An output manipulates the obtained data according to the operation associated with the output The result can then be used...

Page 4: ...output This should describe what the output actually generates Select the operation to be used by the output from the drop down list Select the input from the drop down list In our example below we w...

Page 5: ...pressure sensor data scaled in units of PSI from the Analog 3 Pin 7 input of the 30 2226 CAN Sensor Module to any Gauge item in your Dash setup Modifying the tach output scalar AEM provided dash setu...

Page 6: ...h set up Go to Setup Display CAN Receive Import CAN Select the file 30 2226 CSM6 dbc Open ONLY select the inputs being used See example below Create functions for sensors that are being used The data...

Page 7: ...2 5 2019 DOCUMENT NUMBER 10 2226 2019 AEM Performance Electronics 30 2226 6 Channel CAN Sensor Module Create a new output channel using the new function Assign the new output to an item on the displa...

Page 8: ...8 2 5 2019 DOCUMENT NUMBER 10 2226 2019 AEM Performance Electronics 30 2226 6 Channel CAN Sensor Module System Schematic...

Page 9: ...Power 5V sensor reference power output Analog Inputs 1 2 These inputs have a 2200 Ohm 5V pull up resistor and are suitable for two wire thermistor temperature sensors It is not recommended to connect...

Page 10: ...erature Most non temperature sensors require a simpler linear scaling The AEM CD series of dashes have both of these capabilities please refer to the appropriate documentation Tachometer Input This in...

Page 11: ...4 Air Temp Sensor DTM Style Kit Analog 2200 30 2064 Exhaust Back Pressure Sensor Install Kit Analog 100 000 30 2130 7 100 PSIa or 7 Bar Stainless Sensor Kit Stainless Steel Sensor Body Analog 100 000...

Page 12: ...te 50 Hz FAQ Troubleshooting My CAN Sensor Module doesn t seem to be outputting anything Confirm that your CAN bus is properly terminated and that all nodes are configured for the right bus speed In a...

Page 13: ...y claims to AEM ELECTRONICS must be transportation prepaid and accompanied by dated proof of purchase This w arranty applies only to the original purchaser of product and is non transferable All impli...