5
2/5/2019 - DOCUMENT NUMBER: 10-2226
© 2019 AEM Performance Electronics
30-2226 6 Channel CAN Sensor Module
Click the Insert button to add data points. Only two points are required for a linear function. The data is interpolated.
More points can be added for non-linear functions.
Next go back to the Outputs tab and choose your new function as the Operation for your new Output.
Finally, select the Primary Input which in this case will be AnalogVoltsExt_3
Your new
My Pressure
output can pass pressure sensor data, scaled in units of PSI, from the Analog 3 (Pin 7) input of the
30-2226 CAN Sensor Module to any Gauge item in your Dash setup.
Modifying the tach output scalar
AEM provided dash setup files will include pre-configured tach output scalars. It's very simple to configure your tach input.
Find the EngineSpeed output in the Setup Editor. In the example below you can see it uses a scalar for 8 pulses per
engine cycle. This is typical for a V8 engine using a distributor/coil combination when the tach input to the 30-2226 is
tapped into the coil negative terminal.
If your tach input has a different number of pulses per cycle, simply select from the other available options.