AEM 00.14523.131040 User Manual Download Page 4

aem.eco

LAMBRECHT meteo    

|

    AEM

    |

 

   PRO-WEA

page 

 

4

Mounting of the cup rotor and the wind vane at the sensor

The bores at the cup rotor and the wind vane are attached in such a way that they can only be installed in a certain clear 
position. All 3 screws must be used to fasten the cup rotor resp. the wind vane. Thus the correct direction of rotation is 
guaranteed. The necessary wrench is included in delivery.

Mounting options

Because the installation take place in a dangerous height, the assembly personal must follow the rules for 
prevention of accidents.

I. TRAVERSE WITH SLOTTED BORES

(Id No.: 32.14567.010000)

The traverse has a slotted hole of Ø 30 mm at each of its two ends.

1.  Remove the nut from the sensor. 

2.  Put a sensor with assembled cable sidewise into the bore. 

3. 

Attach the sensor with the flat side of detached nut from the lower side. 

 

Tighten with a suitable tool (wrench size 40), until a twisting safety of the sensor aligned to the north is given.

II. MOUNTING IN BORES

The material thickness for mounting the sensor between the nuts must not exceed 10 mm.

1.  Remove the thread nut from the sensor. 

2.  The sensor with cable-plug connection is led without cable into the bore and fastened by the opposite side with 

the loose nut as under I.3. 

1

Halbrundschraube mit
Innensechskant

round head screw with

hexagon socket

M3x8 DIN7380

2

Schalenstern / cup rotor

3

Schalensternglocke / cup rotor

protective globe

4

Skt-Stiftschlüssel / hex head

wrench

4

2

3

1

3

1

4

2

1

Schraube mit Innensechskant
screw with hexagon socket

M3x12 DIN7380

2

Windfahne / wind vane

3

Windfahnenglocke / wind vane protective globe

4

Skt-Stiftschlüssel / hex head wrench

Summary of Contents for 00.14523.131040

Page 1: ...USER MANUAL Wind Sensors PRO WEA ...

Page 2: ...relectromagneticfieldswhicharebeyondthestandardsand specifications inthetechnicaldata 3 Damagescaused byimproperhandling e g bywrongtools incorrectinstallation incorrectelectrical installation falsepolarity etc 4 Damageswhicharecaused byusingthedevicebeyondthespecifiedoperationconditions Content Warranty 2 FeaturesofthePRO WEAwind sensors 3 Initialoperation 3 Choose installationsite 3 Mountingofth...

Page 3: ... very carefully Choose installation site Generally windmeasuringinstruments should notmeasurethespecificwindconditionsofalimitedarea but indicate thetypicalwindconditionsofawiderarea Thevaluesmeasuredatdifferentplacesmustbecomparable Thus wheninstallingthesensoryoushould makesuretheplaceofinstallationisnotundertheleeofgreatobstacles Thedistance betweentheobstacles andthesensorshouldbe10timesthehei...

Page 4: ...sorwithassembledcablesidewiseintothebore 3 Attach thesensorwiththeflatsideofdetachednutfromthelowerside Tightenwitha suitabletool wrenchsize40 untilatwistingsafetyofthesensoralignedtothenorthisgiven II MOUNTING IN BORES Thematerial thicknessformountingthesensorbetweenthenutsmustnotexceed10mm 1 Remove thethreadnutfromthesensor 2 Thesensorwithcable plugconnectionisledwithoutcableintotheboreandfasten...

Page 5: ...nsensor Thereferencepointcanbeselectedusingatopographicalmap 1 25000 The exactposition ofthereferencepointis determinedusinganamplitudecompassthatcanbeadjustedhorizontally on astand Beware of compass misdirections Whenthenorth directionissetup forthewinddirectionsensor youcanmountingitasunderpoint Mounting options Removeanyadhesivetape Ifyou cannotselectanorthernreferencepointowingtolocalcondition...

Page 6: ...nce freeoperation Wethereforerecommendaregularvisual verification ofthenorthsetupofthewind directionsensoraswellasasensorcalibrationofbothsensortypesevery two years With problems whichcannotsolveyou donothesitatetocontactourLAMBRECHTmeteoserviceunder Tel 49 0 551 4958 0 E mail support lambrecht net Disposal LAMBRECHTmeteoGmbHis listedand registeredattheStiftungElektro AltgeräteRegisterearunder WEE...

Page 7: ...thplugconnection length 12m Flameresistance ofthecable acc toULStyle20549 DIMENSIONED DRAWING Maße ohne Toleranzangabe nach B Maßs Material Bearb Gepr Datum Name Artikelnummer DIN ISO 2768 m Benennung 01 11 2022 curdt Oberfläche Maßzeichnung Kabel Norm Revis 44 5 14 8 12 12 M Dimensional drawings ...

Page 8: ...aem eco LAMBRECHT meteo AEM PRO WEA page 8 ...

Page 9: ...aem eco LAMBRECHT meteo AEM PRO WEA page 9 Electrical connection ...

Page 10: ... seawaterresistantaluminum IP65inverticalpositionofuse M12cableplugconnection stainlesssteelnutandlockwasher Dimensions seedimensionaldrawings Scope of delivery sensor usermanual PARAMETER PRO WEA Wind direction sensor PRO WEA Wind speed sensor Measuring element wind vane dimensionallystable Aluminum speciallycoated three armedcuprotor Aluminumspeciallycoated Measuring range 0 360 0 5 60m S Accura...

Reviews: