aem.eco
LAMBRECHT meteo
|
AEM
|
PROFESSIONAL
page
–
4
Mounting of the cup rotor at the wind speed sensor
The bores at the cup rotor are so attached that the cup rotor can only in a
certain, clear position to be installed. All three screws must be used and
the cup rotor with it be fastened. Thus the correct direction of rotation is
guaranteed. The necessary wrench is included in delivery.
Mounting options
Since installation usually takes place at great heights, the assembly personnel must observe the relevant
safety regulations during installation.
I. MAST OR PIPE MOUNTING
Make sure the device is easily accessible so that you can set up the north direction for the wind direction sensor
and perform any maintenance work. To reach the sensors use a ladder of the appropriate length or a telescoping
working platform of the appropriate height.
Ladders or other lifting helps must be absolutely in order and must be guarantee a secure support! Follow
the rules for prevention of accidents.
Mast or tube (grounded) have an outer Ø of 48-50 mm. A mast adapter (see accessories) is required.
1. Loosen both threaded nuts from the sensor.
2. The sensor with cable plug connection is inserted into the hole (Ø 30 mm) of the adapter without cable.
3.
To fasten the sensor, one of the loosened threaded nuts is screwed from below with the flat side onto the sensor thread
against the inner surface of the adapter, tightened with a suitable tool (SW 36) until there is resistance to twisting of
the aligned sensor.
4.
Finally, it is recommended that the second threaded nut also be countered against the first threaded nut with the flat
side first.
You can also use masts that can turn around their vertical axis or masts consisting of individual segments or
telescoping masts that you can secure after setting up the north direction.