D) REFRESH THE SYSTEM

-- IT IS REQUIRED ONLY FOR CHANGING OPERATION MODE

It is possible to change the current operation mode (Single User or Multi-User Mode) by refreshing the system

with the User Mode Command Code (8900 or 8901) and re-program the keypad with new data.

All the current data in the system will be cleared

and save with the Default

Values once the system is refreshed.

To refresh the system, set system in programming mode and then enter the appropriate

and validate via

key.

The system takes approximate 2 to 3 seconds to refresh itself for the new operation mode. DO NOT
enter any data immediately after the validation

key is pressed until the 2 confirmation beeps are

heard.

After the system is refreshed, it is still in Programming Mode. You can consider it as a new keypad power
up at the first time and program it with new data. Please see the programming "Summary Chart" for details.
You can re-program any individual item in the Summary Chart.

It is necessary to exit the programming mode and save the new data after programming via the

key

NOTE:

except the Master Code

1)

User Mode

Command Code (8900 or 8901)

NOTE:

2)

3)

#

#

*

*

3289 *
8900 #

8901 #

*

3289 *

#

1 05 #

2 3 #
3 2 #

*

----------------- System in programming mode

---------------- System is refreshed for Single User Mode and ready to accept new data after the

confirmation beeps

OR

---------------- System is refreshed for Multi User Mode and ready to accept new data after the

confirmation beeps

---------------------------- All the new data are saved and the keypad is back to normal operation mode

If you need to delete a user who has left the company or who no longer has authority to enter the protected
area:

Enter program mode by keying in your Personal Master Code and the

key

----------------- The keypad is now in the programming mode

Enter the User Number and the

key

If you want to delete User Number 05 from output 1, press

If you want to delete User Number 3 from output 2, press

If you want to delete User Number 2 from output 3, press

Exit the programming mode by press the

key

E) DELETE USER (MULTI-USER MODE)

1)

2)

3)

13

CONNECTING THE REMOTE KEYPAD UNIT(S) TO THE MASTER

UNIT

THE TAMPER SWITCH OF THE REMOTE KEYPAD UNIT

The basic DK-9680 / DK-9880 system comes with one Master unit and one Remote Keypad unit. Actually, each
master unit allows maximum 3 remote keypad units connecting to it. The DK-9680 / DK-9880 system uses current
mode data bus communication, which makes the additional keypad connections very simple, just connecting all the
"DATA" and GND terminals of the keypad units and the master unit in parallel as the diagram shown below. The
keypad units of DK-9680 and DK-9880 can be mixed use with one master unit for multi-station operation.

All the remote keypad units in the system give identical control function to the master unit in normal

operation.

Any one of the remote keypad units in the system can be used for programming. Once the one

has been selected for programming, the other keypads in the system will be disabled until the system exits the
programming mode. Any one of the keypad units can be selected as a programming keypad under one of the
following conditions:

1) When the Personal Master Code has been keyed-in to that keypad unit.

2) After use of the DAP jumper enters to programming mode, all the keypad units in the system are prepared for

the selection. When the one is first keyed-in with any code, it is considered to be selected as the programming
keypad automatically.

Each keypad unit employs a tamper switch which is normally depressed. When the keypad unit is separated from
the mounting box, it will be released and will make the keypad unit to send an alarm command to the Master to
generate alarm output for 60 seconds. The alarm can be stopped by keying-in the User Code 1 before the end of
the alarm time.

"

"

OPERATION --

PROGRAMMING --

14

(OPTIONAL KEYPADS)

GROUND

DATA

KEYPAD 1

(OUTSIDE THE PREMISES)

WEATHERPROOF VERSION

KEYPAD 2

(OTHER LOCATION)

WEATHERPROOF VERSION

KEYPAD 3

(INSIDE THE PREMISES)

SLIM VERSION

DK-9680A / DK-9880A

THE MASTER UNIT ( INSIDE THE PREMISES )

M A I N S

KEY

A R M E D

L O C K

DOOR
BELL

1

2

3

4

5

6

7

8

9

0

#

#

#

Summary of Contents for DK-9680 Series

Page 1: ...controlled by output 1 The circuit is open when the door is open It initiates the following functions 1 When the door is FORCED OPEN the door is opened without the use of a valid code or the EGRESS b...

Page 2: ...T CCESS TO ROGRAMMING 3 STATUS 1 In programming mode 2 Successful key entry 3 Successful code entry 4 Unsuccessful code entry 5 DAP jumper not replaced 6 Standby mode TONES 1 Beep 2 Beeps 5 Beeps Cont...

Page 3: ...ary Mode 601 Output 3 is 1 Second Momentary Mode 70 After 10 Successive False Code The Keypad Locks During 30 Seconds 80 Door Force Open Alarm Detection is Disabled 90 The Door Open Too long Timer is...

Page 4: ...rm enabled k Set the allowable time for door left open for 60 seconds before triggering of the door Open Too Long alarm A SINGLE USER MODE OPERATION An Example 1 Re uirement 8 2 Programming NOTE a Pre...

Page 5: ...door that is equipped with and leave it open for more than 60 seconds the programmed time The alarm starts Close the door the alarm stops automatically This feature reminds the owner to close the door...

Page 6: ...ted Code is Output 3 starts Output 3 stops Output 3 starts Output 3 stops 0321 9270 22898 3289 1 3289 2 3289 3 31223 53221 92 9270 22 22898 User Codes of Group 1 The Corresponding Duress Codes 9270 92...

Page 7: ...the programming mode by press the key E DELETE USER MULTI USER MODE 1 2 3 13 CONNECTING THE REMOTE KEYPAD UNIT S TO THE MASTER UNIT THE TAMPER SWITCH OF THE REMOTE KEYPAD UNIT The basic DK 9680 DK 98...

Page 8: ...contacts Stands for Normally Closed the contact is closed circuit at normal status It is open circuit when activated Stands for Normally Open the contact is open circuit at normal status It is closed...

Reviews: